Purpose: We evaluated the ability of the PRESTO (principles of echo shifting with a train of observations) technique to reveal small veins and microbleeds in the human brain.

Materials And Methods: In an experimental study, we calculated contrast-to-noise ratio (CNR) between a cerebral parenchymal phantom and human venous blood using 3 sequences of 3-dimensional (3D)-PRESTO, 3D-gradient recalled echo (GRE), and 3D-GRE echo-planar imaging (EPI). Then, we examined 7 healthy volunteers and 5 patients with venous angiomas or traumatic brain injuries using the 3D-PRESTO technique. In volunteer studies, MR venographies were reconstructed from 10-mm, 15-mm, and 20-mm thickness data using the minimum-intensity-projection (MinIP) technique. Three radiologists identified deep brain venous anatomy and counted the visible left medullary veins. In clinical studies, we evaluated the lesion conspicuity of small venous diseases and microbleeds.

Results: In the phantom study, 3D-PRESTO showed the highest CNR. In all volunteer studies, the deep brain venous anatomy was readily identified in the MinIP images at each thickness. The mean numbers of counted left medullary veins were 5.1 for 10 mm, 5.9 for 15 mm, and 6.7 for 20 mm in the MinIP images. The difference was significant between 10-mm and 20-mm MinIP images (P=0.02). In patient studies, abnormal small veins and microbleeds were clearly revealed.

Conclusion: High-resolution MR venography using 3D-PRESTO technique can clearly depict small veins and microbleeds in the human brain.

Download full-text PDF

Source
http://dx.doi.org/10.2463/mrms.7.73DOI Listing

Publication Analysis

Top Keywords

3d-presto technique
12
small veins
12
veins microbleeds
12
minip images
12
venography 3d-presto
8
microbleeds human
8
volunteer studies
8
deep brain
8
brain venous
8
venous anatomy
8

Similar Publications

Blood oxygenation level dependent (BOLD) functional magnetic resonance imaging (fMRI) is commonly performed using 2D single-shot echo-planar imaging (EPI). However, single-shot EPI at 7 Tesla (T) often suffers from significant geometric distortions (due to low bandwidth (BW) in the phase-encode (PE) direction) and amplified physiological noise. Recent studies have suggested that 3D multi-shot sequences such as PRESTO may offer comparable BOLD contrast-to-noise ratio with increased volume coverage and decreased geometric distortions.

View Article and Find Full Text PDF

Introduction: Principles of echo shifting with a train of observations (PRESTO) sequence has long echo time which emphasizes the effect of T2* relaxation time and contribute to its high sensitivity to the susceptibility change. The aim of our study was to evaluate the ability of 3D-PRESTO sequence in detecting putaminal hypointensity in patients with parkinsonian variant of multiple system atrophy (MSA-P) and in discriminating between MSA-P and Parkinson's disease (PD).

Methods: The signal intensity of the putamen and localization of abnormality were evaluated on 3D-PRESTO, T2*-weighted (T2*W), and T2-weighted (T2W) sequences in ten patients with MSA-P, 14 with PD, and ten controls.

View Article and Find Full Text PDF

Purpose: We evaluated the ability of the PRESTO (principles of echo shifting with a train of observations) technique to reveal small veins and microbleeds in the human brain.

Materials And Methods: In an experimental study, we calculated contrast-to-noise ratio (CNR) between a cerebral parenchymal phantom and human venous blood using 3 sequences of 3-dimensional (3D)-PRESTO, 3D-gradient recalled echo (GRE), and 3D-GRE echo-planar imaging (EPI). Then, we examined 7 healthy volunteers and 5 patients with venous angiomas or traumatic brain injuries using the 3D-PRESTO technique.

View Article and Find Full Text PDF

A major impetus in functional MRI development is to enhance sensitivity to changes in neural activity. One way to improve sensitivity is to enhance contrast to noise ratio, for instance by increasing field strength or the number of receiving coils. If these parameters are fixed, there is still the possibility to optimize scans by altering speed or signal strength [signal-to-noise ratio (SNR)].

View Article and Find Full Text PDF

The authors studied a patient with musicogenic epilepsy triggered by one specific musical piece using 3D PRESTO fMRI. During epileptic aurae initiated by the stimulus, signal increases were found in the left anterior temporal lobe, correlating with ictal EEG and SPECT showing a left anterior temporal focus, and the right gyrus rectus. Because fMRI indicated a cascade of recruitment of the ventral frontal lobes by epileptogenic music, left anterior temporal lobe activity could be secondary to a right gyrus rectus focus, possibly triggered by emotional processing of music.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!