A common assessment of postural control often involves subjects standing on a compliant surface, such as a foam block, to make balance tests more challenging. However, the physical properties of the foam block used by different researchers can vary considerably. The objective of this study was to provide an initial approach for investigating whether two of the foam properties, i.e. density and elastic modulus, influenced recorded anteroposterior and lateral torque variance with eyes open and eyes closed. Thirty healthy adults (mean age 22.5 years) were assessed with posturography using three different types of foam block placed on a force platform. These blocks were categorised: firm foam, medium foam and soft foam by their elastic modulus. To investigate the spectral characteristics of recorded body movements, variance values were calculated for total movements, movements <0.1Hz and movements >0.1Hz. Results showed that anteroposterior and lateral torque variances >0.1Hz were larger when standing on the firm foam compared with medium and soft foam and in turn were larger on the medium foam compared with the soft foam with eyes closed. Moreover, GLM and correlation analysis demonstrated that the properties of the foam blocks affected anteroposterior torque variance >0.1Hz and lateral torque variance in all frequency ranges. In addition, the stabilising effect of vision in the anteroposterior direction had a greater influence when the subjects' stability was increasingly challenged by the support surface, as illustrated by the higher torque variance values. In conclusion, caution should be taken when analysing balance deficits with foam test setups, because the foam properties may influence the recorded body movements.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.gaitpost.2008.04.018 | DOI Listing |
This study investigates the impact of the weight and centre of mass (COM) position of Head-Mounted Displays (HMDs) on the subjective evaluation of users during prolonged wearing tasks. This study involved 88 participants completing 1860 sets of experiments under three conditions: sitting still, turning the head, and moving, providing subjective evaluations of wearing HMDs. A static torque testing device was used to simulate neck torque under flexion states.
View Article and Find Full Text PDFJ Craniofac Surg
December 2024
Department of Oral and Maxillofacial Surgery, College of Dentistry, King Saud University.
Objectives: This study aimed to evaluate the osseointegration properties of titanium bone implants coated with carob-mediated calcium hydroxide nanoparticles biomechanically, radiographically, and histologically on rabbit tibias.
Material And Methods: Forty coated and forty uncoated titanium alloy bone implants were inserted into 20 New Zealand rabbits; each tibia received 2 implants. The rabbits were sacrificed after 4 or 8 weeks, and samples were retrieved for biomechanical evaluation through removal torque test to assess the bond between implant and bone, radiographic evaluation through microcomputed tomography analysis to compare the bone-to-implant contact percentage and bone volume of the peri-implant area, scanning electron microscopic and histologic evaluation through hematoxylin and eosin stain.
J Endod
December 2024
Department of Endodontics, Fluminense Federal University, Niteroi, Brazil.
Introduction: This study aimed to evaluate the mechanical properties of Reciproc, Reciproc Blue, One RECI, and R-Motion, specifically focusing on their flexibility and buckling resistance and to assess their torsional fatigue behavior under 2 different reciprocation angles (150°/30° or 70°/30°).
Methods: A total of 160 instruments (40 per brand) were tested. Flexion and buckling tests were conducted using a Universal testing machine (DL 200 MF).
Front Neurol
December 2024
Brain Rehabilitation Research Center, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, FL, United States.
Knee Surg Sports Traumatol Arthrosc
December 2024
Mechanical Engineering Department, Biomechanics Group, Imperial College, London, UK.
Purpose: High-grade femoral trochlear dysplasia is associated with anterior knee pain, patellar maltracking, instability and the development of osteoarthritis. Scientific studies have signified the importance of trochlear resection on the knee extensor mechanism, and dysplasia can be addressed by a groove-deepening trochleoplasty. Alternatively, tibial tubercle anteriorisation has been proposed to reduce patellofemoral joint (PFJ) pressure and alleviate pain from osteoarthritis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!