The present study aimed at assessing the pharmacokinetics (PK) and safety pharmacodynamics (PD) of 24 microg formoterol delivered via a Novolizer and via an Aerolizer in healthy subjects. This was a randomized, open-label, crossover study. Beside PK, serum potassium, and glucose profiles, vital signs, and ECG were recorded. Twenty-nine subjects (15 males) were enrolled. The inhalation maneuver had to be repeated by 19 subjects using the Aerolizer and 1 subject using a Novolizer. While eight (28%) subjects completely failed to inhale correctly via the Aerolizer (four were identified by the investigators immediately after inhalation, another four by bioanalytics later), all did it correctly via the Novolizer. The bioanalytical evaluation indicated two distinct serum peaks. The shapes of serum concentration-time profiles were more homogeneous after inhaling via the Novolizer than via the Aerolizer. After adjusting for the delivered dose the Cmax of formoterol predicting pulmonary absorption was higher after the Novolizer than after the Aerolizer, while the average AUC0-infinity levels indicating total systemic exposure were equivalent. There was no evidence for different pharmacodynamic behavior with respect to serum potassium and glucose profiles, vital signs, and ECG. The Novolizer yields higher pulmonary absorption of formoterol than the Aerolizer and equivalent safety profiles. Considering the lower variability of PK profiles and the higher proportion of correct inhalations, formoterol is more reliably inhaled via Novolizer.

Download full-text PDF

Source
http://dx.doi.org/10.1089/jamp.2008.0690DOI Listing

Publication Analysis

Top Keywords

novolizer aerolizer
12
pharmacokinetics safety
8
safety pharmacodynamics
8
formoterol delivered
8
serum potassium
8
potassium glucose
8
glucose profiles
8
profiles vital
8
vital signs
8
signs ecg
8

Similar Publications

Checklists for the Assessment of Correct Inhalation Therapy.

Pneumologie

February 2017

Kliniken der Stadt Köln gGmbH - Lungenklinik, Universität Witten/Herdecke, Ostmerheimer Strasse 200, 51109 Köln.

 For the long-term treatment of obstructive lung diseases inhalation therapy with drugs being delivered directly to the lungs as an aerosol has become the method of choice. However, patient-related mistakes in inhalation techniques are frequent and recognized to be associated with reduced disease control. Since the assessment of patient-mistakes in inhalation has yet not been standardized, the present study was aimed at developing checklists for the assessment of correct inhalation.

View Article and Find Full Text PDF

Inhaler devices in asthma and COPD--an assessment of inhaler technique and patient preferences.

Respir Med

July 2014

CIDES - Centro de Investigação em Tecnologias e Sistemas de Informação & CINTESIS, Faculdade de Medicina da Universidade do Porto, Porto, Portugal; Unidades de Imunoalergologia, CUF Porto, Porto, Portugal. Electronic address:

Background: Incorrect use of inhaler devices remains an obstacle for respiratory diseases management. We aimed to evaluate the frequency of inhaler technique errors; to determine the devices perceived as the easiest and favourite to use; to study the association of device type, demographics and patient preferences with inhaler technique (IT).

Methods: Cross-sectional assessment of 301 adults, with asthma (194) or chronic pulmonary obstructive disease, undergoing treatment with Aerolizer®, Autohaler®, Breezehaler®, Diskus®, Handihaler®, MDI without spacer, Miat-haler®, Novolizer®, Respimat® and/or Turbohaler®.

View Article and Find Full Text PDF

The aim of this study was to evaluate and modify commercial dry powder inhalers (DPIs) for the aerosolization of a submicrometer excipient enhanced growth (EEG) formulation. The optimized device and formulation combination was then tested in a realistic in vitro mouth-throat - tracheobronchial (MT-TB) model. An optimized EEG submicrometer powder formulation, consisting of albuterol sulfate (drug), mannitol (hygroscopic excipient), l-leucine (dispersion enhancer) and poloxamer 188 (surfactant) in a ratio of 30:48:20:2 was prepared using a Büchi Nano spray dryer.

View Article and Find Full Text PDF

Background: A new in vitro test method for dry powder inhalers (DPIs) was recently found to be predictive of the published in vivo results for Budelin Novolizer. The present study was intended to assess the method's robustness by evaluating correlations between average drug deposition in vitro and in vivo from five different DPIs.

Methods: In vitro drug deposition from five marketed DPIs was assessed in a realistic physical airway model of a "medium" sized adult in an experimental setup that allowed deposition to be characterized regionally for carefully selected simulated air flow rate versus time profiles.

View Article and Find Full Text PDF

The present study aimed at assessing the pharmacokinetics (PK) and safety pharmacodynamics (PD) of 24 microg formoterol delivered via a Novolizer and via an Aerolizer in healthy subjects. This was a randomized, open-label, crossover study. Beside PK, serum potassium, and glucose profiles, vital signs, and ECG were recorded.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!