Background, Aim And Scope: Once they have been generated, polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) and other persistent organic pollutants (POPs) can persist in soils and sediments and in waste repositories for periods extending from decades to centuries. In 1994, the US EPA concluded that contaminated sites and other reservoirs are likely to become the major source of contemporary pollution problems with these substances. With this in mind, this article is the first in a new series in ESPR under the title 'Case Studies on Dioxin and POP Contaminated Sites--Contemporary and Future Relevance and Challenges', which will address this important issue. The series will document various experiences from sites contaminated with PCDD/F and other POPs. This article provides an overview of the content of the articles comprising the series. In addition, it provides a review of the subject in its own right and identifies the key issues arising from dioxin/POP-contaminated sites. Additionally, it highlights the important conclusions that can be drawn from these examples. The key aim of this article and of the series as a whole is to provide a comprehensive overview of the types of PCDD/F contaminated sites that exist as a result of historical activities. It details the various processes whereby these sites became contaminated and attempts to evaluate their contemporary relevance as sources of PCDD/Fs and other POPs. It also details the various strategies used to assess these historical legacies of contamination and the concepts developed, or which are under development, to effect their remediation.

Main Features: Special sessions on 'Contaminated sites--Cases, remediation, risk and policy' were held at the DIOXIN conferences in 2006 and 2007, and this theme will be continued at DIOXIN 2008 to be held in Birmingham. Selected cases from the approximately 70 contributions made to these sessions, together with some additional invited case studies are outlined together with the key issues they raise. By evaluating these cases and adding details of experiences published in the current literature, an overview will be given of the different features and challenges of dioxin and POP-contaminated sites.

Results: This article provides a systematic categorisation of types of PCDD/F and POP-contaminated sites. These are categorised according to the chemical or manufacturing process, which generated the PCDD/Fs or POPs and also includes the use and disposal aspects of the product life cycle in question. The highest historical PCDD/F and dioxin-like polychlorinated biphenyl (PCB) contamination burdens have arisen as a result of the production of chlorine and of chlorinated organic chemicals. In particular, the production of chlorinated pesticides, PCBs and the related contaminated waste streams are identified being responsible for historical releases of toxic equivalents (TEQs) at a scale of many tonnes. Along with such releases, major PCDD/F contaminated sites have been created through the application or improper disposal of contaminated pesticides, PCBs and other organochlorine chemicals, as well through the recycling of wastes and their attempted destruction. In some extreme examples, PCDD/F contaminated sites have also resulted from thermal processes such as waste incinerators, secondary metal industries or from the recycling or deposition of specific waste (e.g. electronic waste or car shredder wastes), which often contain chlorinated or brominated organic chemicals. The examples of PCDD/F and dioxin-like PCB contamination of fish in European rivers or the impact of contaminated sites upon fishing grounds and upon other food resources demonstrate the relevance of these historical problems to current and future human generations. Many of the recent food contamination problems that have emerged in Europe and elsewhere demonstrate how PCDD/F and dioxin like PCBs from historical sources can directly contaminate human and animal feedstuffs and indeed highlight their considerable contemporary relevance in this respect. Accordingly, some key experiences and lessons learnt regarding the production, use, disposal and remediation of POPs from the contaminated sites are summarised.

Discussion: An important criterion for evaluating the significance and risks of PCDD/Fs and other POPs at contaminated sites is their present or future potential for mobility. This, in turn, determines to a large degree their propensity for off-site transport and environmental accessibility. The detailed evaluation of contaminated site cases reveals different site-specific factors, which influence the varied pathways through which poor water-soluble POPs can be mobilised. Co-contaminants with greater water solubility are also typically present at such sites. Hence, pumping of groundwater (pump and treat) is often required in addition to attempting to physically secure a site. At an increasing number of contaminated sites, securing measures are failing after relatively short time spans compared to the time horizon, which applies to persistent organic pollutant contamination. Due to the immense costs and challenges associated with remediation of contaminated sites 'monitored natural attenuation' is increasingly gaining purchase as a conceptual remediation approach. However, these concepts may well prove limited in their practical application to contaminated sites containing persistent organic pollutants and other key pollutants like heavy metals.

Conclusions: It is inevitable, therefore, that dioxin/POP-contaminated sites will remain of contemporary and future relevance. They will continue to represent an environmental issue for future generations to address. The securing and/or remediation of dioxin/POP-contaminated sites is very costly, generally in the order of tens or hundreds of millions of dollars. Secured landfills and secured production sites need to be considered as constructions not made for 'eternity' but built for a finite time scale. Accordingly, they will need to be controlled, supervised and potentially repaired/renewed. Furthermore, the leachates and groundwater impacted by these sites will require ongoing monitoring and potential further remediation. These activities result in high maintenance costs, which are accrued for decades or centuries and should, therefore, be compared to the fully sustainable option of complete remediation. The contaminated site case studies highlight that, while extensive policies and established funds for remediation exist in most of the industrialised western countries, even these relatively well-regulated and wealthy countries face significant challenges in the implementation of a remediation strategy. This highlights the fact that ultimately only the prevention of contaminated sites represents a sustainable solution for the future and that the Polluter Pays Principle needs to be applied in a comprehensive way to current problems and those which may emerge in the future.

Recommendations And Perspectives: With the continuing shift of industrial activities in developing and transition economies, which often have poor regulation (and weak self-regulation of industries), additional global challenges regarding POPs and other contaminated sites may be expected. In this respect, a comprehensive application of the "polluter pays principle" in these countries will also be a key to facilitate the clean-up of contaminated areas and the prevention of future contaminated sites. The threats and challenges of contaminated sites and the high costs of securing/remediating the problems highlight the need for a comprehensive approach based upon integrated pollution prevention and control. If applied to all polluting (and potentially polluting) industrial sectors around the globe, such an approach will prove to be both the cheapest and most sustainable way to underpin the development of industries in developing and transition economies.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11356-008-0024-1DOI Listing

Publication Analysis

Top Keywords

contaminated sites
56
sites
23
contaminated
22
future relevance
12
persistent organic
12
dioxin/pop-contaminated sites
12
pcdd/f contaminated
12
pcdd/fs pops
12
pops contaminated
12
will
10

Similar Publications

Water quality assessment of rooftop harvested rainwater across different roof types in a semi-arid region of South Africa.

Water Environ Res

January 2025

Water and Environmental Management Research Group, Faculty of Science, Engineering and Agriculture, University of Venda, Thohoyandou, South Africa.

Uneven distribution of precipitation and climate change have led to water shortages, adversely impacting numerous countries worldwide. Rooftop rainwater harvesting (RWH) has emerged as a crucial method for providing water for domestic uses. However, there are concerns about the quality of rainwater collected from roofs, as it may be contaminated with pollutants such as metals and microbiological pathogens.

View Article and Find Full Text PDF

The efficacy of traceability analysis is often limited by a lack of information on influencing factors for heavy metal (HM) contaminations in soil, such as spatial correlations between HM concentrations and influencing factors. To overcome this limitation, a novel data-driven framework was established to identify influencing factors for soil HM concentrations in an industrialised study area, in Guangdong Province, China, mainly using random forest (RF) and bivariate local Moran's I (BLMI) on the basis of the 577 soil samples and the 18 environmental covariates. The quantitative contributions of the 18 influencing factors for the Cd, As, Pb, and Cr concentrations were determined by the optimised RF.

View Article and Find Full Text PDF

Polychlorinated naphthalenes (PCNs) and polychlorinated biphenyls (PCBs) in surface soils and street dusts in Detroit, Michigan.

Sci Total Environ

January 2025

Department of Environmental Health Sciences, School of Public Health, University of Michigan, Ann Arbor, MI, 48109, United States. Electronic address:

Polychlorinated naphthalenes (PCNs) and polychlorinated biphenyls (PCBs) are toxic contaminants that were produced and used in large quantities for their stability, inertness, and other desirable electrical, cooling, and lubricating properties. Due to their environmental persistence and improper disposal, these contaminants have become broadly distributed in the environment. This study examines the levels, composition, distribution, and potential sources of these compounds in surface soils and street dusts collected at 19 residential and industrial areas in Detroit, Michigan.

View Article and Find Full Text PDF

Quantification of denitrification rate in shallow groundwater using the single-well, push-pull test technique.

J Contam Hydrol

January 2025

Environmental Science, School of Agriculture and Environment, Massey University, Private Bag 11 222, Palmerston North 4442, New Zealand.

Denitrification has been identified as a significant nitrate attenuation process in groundwater systems. Hence, accurate quantification of denitrification rates is consequently important for the better understanding and assessment of nitrate contamination of groundwater systems. There are, however, few studies that have investigated quantification of shallow groundwater denitrification rates using different analytical approaches or assuming different kinetic reaction models.

View Article and Find Full Text PDF

Toxic tuna tales: Tracing microplastic pathways in mackerel tuna (Euthynnus affinis), longtail tuna (Thunnus tonggol), and bullet tuna (Auxis rochei).

Mar Pollut Bull

January 2025

Faculty of Science and Marine Environment, Universiti Malaysia Terengganu, 21030 Kuala Terengganu, Terengganu, Malaysia; UMT-OUC Joint Academic Center for Marine Studies, Institute of Climate Adaptation and Marine Biotechnology (ICAMB), Universiti Malaysia Terengganu, 21030 Kuala Terengganu, Terengganu, Malaysia.

Casting a shadow upon marine ecosystems worldwide, microplastic pollution emerges as a formidable threat, yet its repercussions on commercially significant marine fish remain largely unexplored. This investigation delves into the realm of microplastic contamination within three tuna species (Euthynnus affinis, Thunnus tonggol, and Auxis rochei) inhabiting Malaysian waters, with a keen focus on the gastrointestinal tract (GIT), gills, and edible muscle. These species were chosen due to their significant ecological roles and considerable commercial value, being extensively fished and widely consumed across global regions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!