On the calibration process of film dosimetry: OLS inverse regression versus WLS inverse prediction.

Phys Med Biol

Department of Medical Physics, Ghent University, Proeftuinstraat 86, B-9000 Gent, Belgium.

Published: July 2008

The purpose of this study was both putting forward a statistically correct model for film calibration and the optimization of this process. A reliable calibration is needed in order to perform accurate reference dosimetry with radiographic (Gafchromic) film. Sometimes, an ordinary least squares simple linear (in the parameters) regression is applied to the dose-optical-density (OD) curve with the dose as a function of OD (inverse regression) or sometimes OD as a function of dose (inverse prediction). The application of a simple linear regression fit is an invalid method because heteroscedasticity of the data is not taken into account. This could lead to erroneous results originating from the calibration process itself and thus to a lower accuracy. In this work, we compare the ordinary least squares (OLS) inverse regression method with the correct weighted least squares (WLS) inverse prediction method to create calibration curves. We found that the OLS inverse regression method could lead to a prediction bias of up to 7.3 cGy at 300 cGy and total prediction errors of 3% or more for Gafchromic EBT film. Application of the WLS inverse prediction method resulted in a maximum prediction bias of 1.4 cGy and total prediction errors below 2% in a 0-400 cGy range. We developed a Monte-Carlo-based process to optimize calibrations, depending on the needs of the experiment. This type of thorough analysis can lead to a higher accuracy for film dosimetry.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/53/14/015DOI Listing

Publication Analysis

Top Keywords

inverse regression
16
inverse prediction
16
ols inverse
12
wls inverse
12
calibration process
8
film dosimetry
8
inverse
8
prediction
8
ordinary squares
8
simple linear
8

Similar Publications

[F]FDG PET/CT versus Dynamic Contrast-Enhanced CT for the diagnosis of solitary pulmonary Nodule: A Head-to-Head comparative Meta-Analysis.

Eur J Radiol

January 2025

Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Electronic address:

Purpose: This head-to-head comparative meta-analysis aimed to evaluate the comparative diagnostic efficacy of [F]FDG PET/CT and dynamic contrast-enhanced CT(DCE-CT) for the differentiation between malignant and benign pulmonary nodules.

Methods: An extensive search was conducted in the PubMed, Embase, and Web of Science to identify available publications up to March 23, 2024. Studies were included if they evaluated the diagnostic efficacy of [F]FDG PET/CT and DCE-CT for the characterization of pulmonary nodules.

View Article and Find Full Text PDF

Objective: The oxidative balance score (OBS) has emerged as a novel marker for assessing oxidative stress status. This study aimed to investigate the association of OBS with systolic blood pressure (SBP), diastolic blood pressure (DBP), all-cause, and cardiovascular disease mortality in hypertensive patients.

Methods: We conducted an analysis of data from 7602 hypertensive patients from the National Health and Nutrition Examination Survey (NHANES) 2005-2018.

View Article and Find Full Text PDF

Background: The rising prevalence of depression among cancer patients is alarming. This study examines the relationship between the Oxidative Balance Score (OBS)-a composite measure of dietary and lifestyle factors-and depression, including specific depressive symptoms in this population.

Methods: Data were analyzed from 3,280 adult cancer patients collected in NHANES from 2005-2020.

View Article and Find Full Text PDF

Purpose: To evaluate levels of 3 tear-soluble neuropeptides in dry eye patients and to identify the correlations with clinical signs and symptoms.

Methods: A total of 16 dry eye patients and 12 healthy volunteers were enrolled. Dry eye disease (DED) diagnosis was based on the 2017 Report of the Tear Film & Ocular Surface Society International Dry Eye Workshop (TFOS DEWS II).

View Article and Find Full Text PDF

Background: Digital health technologies hold promises for enhancing healthcare and self-management in diabetes. However, disparities in Electronic Health Literacy (EHL) exist among diabetes populations. This study investigates EHL trends and demographic differences among adults with diabetes in the United States from 2011 to 2018.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!