Effect of different traversal schemes in integral image coding.

Appl Opt

Department of Informatics and Telecommunications, National and Kapodistrian University of Athens, Panepistimiopolis, Ilissia, Greece.

Published: July 2008

AI Article Synopsis

Article Abstract

Integral imaging (InIm) is a highly promising technique for the delivery of three-dimensional (3D) image content. During capturing, different views of an object are recorded as an array of elemental images (EIs), which form the integral image. High-resolution InIm requires sensors with increased resolution and produces huge amounts of highly correlated data. In an efficient encoding scheme for InIm compression both inter-EI and intra-EI correlations have to be properly exploited. We present an EI traversal scheme that maximizes the performance of InIm encoders by properly rearranging EIs to increase the intra-EI correlation of jointly coded EIs. This technique can be used to augment performance of both InIm specific and properly adapted general use encoder setups, used in InIm compression. An objective quality metric is also introduced for evaluating the effects of different traversal schemes on the encoder performance.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.47.000d28DOI Listing

Publication Analysis

Top Keywords

traversal schemes
8
integral image
8
inim compression
8
performance inim
8
inim
6
schemes integral
4
image coding
4
coding integral
4
integral imaging
4
imaging inim
4

Similar Publications

An automated micro-tweezers system with a flexible workspace would benefit the intelligent sorting of live cells. Such micro-tweezers could employ a forced vortex strong enough to capture a single cell. Furthermore, addressable control of the position to the vortex would constitute a robotic system.

View Article and Find Full Text PDF

Proton radiography is a central diagnostic technique for measuring electromagnetic (EM) fields in high-energy-density, laser-produced plasmas. In this technique, protons traverse the plasma where they accumulate small EM deflections which lead to variations in the proton fluence pattern on a detector. Path-integrated EM fields can then be extracted from the fluence image through an inversion process.

View Article and Find Full Text PDF

Electron Airy beams and electron vortex beams are commonly generated using phase masks that imprint a transverse modulation on the particle wave function. Plasmons sustained by nanostructured conductors facilitate substantial interactions with free electrons, enabling considerable transverse modulation of the electron wave function. Consequently, electron Airy and vortex beams can also be produced through interactions between electrons and structured plasmonic fields.

View Article and Find Full Text PDF

Ghost imaging enables the imaging of an object using intensity correlations between a single-pixel detector placed behind the object and a camera that records the light that did not interact with the object. The object and the camera are often placed at conjugate planes to ensure correlated illumination patterns. Here, we show how the combined effect of optical reciprocity and the memory effect in a random medium gives rise to correlations between two beams that traverse the random medium in opposite directions.

View Article and Find Full Text PDF

Reconfigurable ultrasound focusing effect through acoustic barriers.

Ultrasonics

January 2025

Department of Mechanical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong Special Administrative Region. Electronic address:

The low transmission efficiency of ultrasonic waves in waveguides of a high acoustic impedance (referred to as dense materials), due to the impedance mismatch between the background media and the dense materials, poses a significant obstacle to practical applications of high-intensity focused ultrasound (HIFU) such as ultrasound therapy or medical imaging. To address this challenge, we present an inverse optimization scheme for fabrication of novel acoustic meta-lenses, enabling strengthened penetration and enhanced focusing of ultrasonic waves when the waves traverse barriers. Both simulation and experiment validate the effectiveness of the developed meta-lenses which are annexed to hemispherical plates, and demonstrate an enhanced transmission of the sound power by an order of magnitude compared to a scenario without the use of the meta-lens.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!