This study compared peak compression load in Newtons and stiffness in Newtons/millimeter for varying interfragmental screw sizes versus mini rail external fixation for the surgical treatment of Jones fifth metatarsal fractures. Four groups were included into this study: (1) Jones fracture with external fixation (Orthofix, Inc., McKinney, TX); (2) Jones fracture with 4.5-mm interfragmental cannulated screw; (3) Jones fracture with 5.5-mm interfragmental cannulated screw; and (4) Jones fracture with 6.5-mm interfragmental cannulated screw. There was no statistically significant difference between the peak compression achieved with the different groups of interfragmental cannulated screws: 4.5-mm interfragmental cannulated screw = 30.56 (+/- 9.40) N; 5.5-mm interfragmental cannulated screw = 30.69 (+/- 10.75) N; and 6.5-mm interfragmental cannulated screw = 32.84 (+/- 9.65) N. When comparing the compression achieved with the different groups of interfragmental cannulated screws to that achieved with the small rail external fixator (69.70 [+/- 14.69] N), a statistically significant difference was noted. There was no statistically significant difference in regard to stiffness (Newtons/millimeter) noted between the intramedullary cannulated screw groups: 4.5 cannulated screw 5.25 (+/- 1.96), 5.5 cannulated screw 5.50 (+/- 2.01), and 6.5 cannulated screw 6.75 (+/- 2.60). A statistically significant difference was noted when the stiffness (Newtons/millimeter) of the rail external fixator (12.69 (+/- 4.52) was compared to the stiffness achieved with the different interfragmental screws. The results indicated that the small rail external fixation device provided increased compression and an increased ability to resist bending when compared to the different intramedullary cannulated screws.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jfas.2008.04.005DOI Listing

Publication Analysis

Top Keywords

cannulated screw
40
interfragmental cannulated
32
rail external
20
cannulated screws
16
external fixation
16
jones fracture
16
statistically difference
16
cannulated
14
stiffness newtons/millimeter
12
screw
11

Similar Publications

Analysis of Extreme Beak Calcaneal Fracture (Type 2-Lee) Fixed with Cannulated Cancellous Screws: An Original Research Article.

J Orthop Case Rep

January 2025

Department of Orthopaedics, Vinayaka Mission's Medical College and Hospital, Vinayaka Mission's Research Foundation (DU), Karaikal , Puducherry, India.609609.

Introduction: Extreme beak calcaneal fractures (Type 2 Lee's tuberosity avulsion fractures) are rare injuries, accounting for only 1.3-3% of all calcaneal fractures. These injuries are considered as surgical emergency as they can lead to significant functional impairment and soft-tissue compromise if not promptly managed.

View Article and Find Full Text PDF

Introduction: Posterior cruciate ligament (PCL) avulsion fractures of the tibia with ipsilateral tibial shaft represent a rare but challenging orthopedic injury, necessitating careful consideration of surgical interventions for optimal outcomes. This case report presents the successful management of tibial shaft fracture (proximal 1/3rd junction) along with ipsilateral PCL avulsion fracture of tibia using a novel approach using open reduction internal fixation (ORIF) of tibial shaft with Locking compression plate (LCP) with cannulated cancellous screw and spiked washer fixation of PCL avulsion. There are no case reports or research articles available for the management of PCL avulsion fracture of tibia associated with ipsilateral tibial shaft fracture.

View Article and Find Full Text PDF

A 3D-printed guide is an effective method for accurately placing pedicle screws in dog vertebrae. While a conventional drill guide allows precise pilot hole formation, it can lead to potential screw wobbling during insertion. In this study, we applied a technique that assists with both drilling and screw insertion, and we compared the accuracy of screw placement using this approach with that achieved by the conventional drill guide.

View Article and Find Full Text PDF

Purpose: This study aims to describe a fixation technique for coronoid fractures using suture buttons, and to biomechanically evaluate this technique in comparison to screw fixation as a time-zero pilot study.

Methods: An O'Driscoll type 2 anteromedial coronoid facet (AMCF) fracture was simulated in 20 fresh-frozen human elbows. The specimens were randomized into two groups and fracture fixation was performed with either a suture button system or a 3.

View Article and Find Full Text PDF

Pediatric elbow fractures are quite common, accounting for up to 34% of bone fractures in children. Among these, acute lateral humeral condyle (LHC) fractures represent up to 22%. The accurate diagnosis and early treatment of LHC fractures are crucial due to the potential for abnormal growth and significant long-term impacts on joint motion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!