Introduction And Objectives: Ostium secundum atrial septal defects require closure. Echocardiographic studies have reported that, in 7% of cases, the Amplatzer occluder is orientated perpendicular to the rim of the defect. This article describes the use of an ancillary technique involving a balloon catheter that enables the Amplatzer device to be positioned transversely.
Methods: We report six patients with an ostium secundum atrial septal defect in whom echocardiographic imaging showed that the Amplatzer device was positioned perpendicular to the rim of the defect. To correct the device's orientation, we used an ancillary maneuver that involved placing a balloon catheter at the device's lower edge, thereby inducing it to adopt a transverse position and undergo successful implantation.
Results: In all cases, the ancillary balloon catheter technique enabled the device to adopt the correct transverse orientation, thereby facilitating successful implantation.
Conclusions: The ancillary balloon catheter technique is useful for ensuring that Amplatzer devices adopt a transverse orientation when echocardiography shows the device to be persistently orientated perpendicular to the rim of the septal defect.
Download full-text PDF |
Source |
---|
J Mol Cell Cardiol
December 2024
A.I.Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland; Heart Centre and Gene Therapy Unit, Kuopio University Hospital, Kuopio, Finland. Electronic address:
Background: Coronary stenting operations have become the main option for the treatment of coronary heart disease. Vessel recovery after stenting has emerged as a critical factor in reducing possible complications. In this study, we evaluated the feasibility, safety and efficacy of locally administered intraluminal gene therapy delivered using a specialized infusion balloon catheter.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Cardiovascular Medicine, Sendai Kousei Hospital, 1-20 Tsutsumidori-amamiya, Aoba Ward, Sendai, Miyagi 9810914, Japan.
Background: Transcatheter edge-to-edge mitral valve repair (M-TEER) using the MitraClip system is primarily performed using the transfemoral approach. However, when this approach is not feasible, the transjugular approach can be used as an alternative.
Case Summary: A 57-year-old man presented with heart failure and persistent New York Heart Association class IV symptoms, refractory to guideline-directed medical therapy, intravenous therapy, and intra-aortic balloon pumping.
Catheter Cardiovasc Interv
January 2025
Center for Structural Heart Disease, Henry Ford Health System, Detroit, Michigan, USA.
Background: Protruding coronary artery stents can adversely affect transcatheter aortic valve replacement (TAVR) procedure. Current evidence on the topic is limited.
Aims: We aim to study the clinical feasibility and safety of flaring of protruding coronary artery stents before TAVR to reduce interaction with transcatheter heart valves.
J Vasc Interv Radiol
January 2025
Division of Vascular and Interventional Radiology, Department of Radiology, Baylor College of Medicine, Houston, Texas. Electronic address:
Korean Circ J
November 2024
Department of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Background And Objectives: Traditional manual percutaneous coronary intervention (PCI) exposes operators to significant radiation and physical stress. The recently developed Advanced Vascular Intervention Assist Robot (AVIAR) 2.0 system in South Korea aimed to overcome these issues by evaluating its safety and feasibility in a clinical setting.