Even though there is no direct evidence to prove the cellular and molecular changes induced by radiofrequency (RF) radiation itself, we cannot completely exclude the possibility of any biological effect of mobile phone frequency radiation. We established a carousel-type exposure chamber for 849 MHz or 1763 MHz of mobile phone RF radiation to expose RF to the heads of C57BL mice. In this chamber, animals were irradiated intermittently at 7.8 W/kg for a maximum of 12 months. During this period, the body weights of 3 groups-sham, 849 MHz RF, and 1763 MHz RF-did not show any differences between groups. The brain tissues were obtained from 3 groups at 6 months and 12 months to examine the differences in histology and cell proliferation between control and RF exposure groups, but we could not find any change upon RF radiation. Likewise, we could not find changes in the expression and distribution of NeuN and GFAP in hippocampus and cerebellum, or in cell death by TUNEL assay in RF exposure groups. From these data, we conclude that the chronic exposure to 849 MHz and 1763 MHz RF radiation at a 7.8 W/kg specific absorption rate (SAR) could not induce cellular alterations such as proliferation, death, and reactive gliosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2679292PMC
http://dx.doi.org/10.3858/emm.2008.40.3.294DOI Listing

Publication Analysis

Top Keywords

849 mhz
16
mhz 1763
16
1763 mhz
16
exposure 849
8
mhz
8
radiofrequency radiation
8
cell death
8
cell proliferation
8
mobile phone
8
exposure groups
8

Similar Publications

The repeatability of periodontal imaging with intraoral ultrasound scanning.

Clin Oral Investig

February 2024

School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada.

Objective: Ultrasound is a non-invasive and low-cost diagnostic tool widely used in medicine. Recent studies have demonstrated that ultrasound imaging might have the potential to be used intraorally to assess the periodontium by comparing it to current imaging methods. This study aims to characterize the repeatability of intraoral periodontal ultrasound imaging.

View Article and Find Full Text PDF

A validation of an entropy-based artificial intelligence for ultrasound data in breast tumors.

BMC Med Inform Decis Mak

January 2024

The Second Clinical Medical College, Jinan University, 518020, Shenzhen, China.

Background: The application of artificial intelligence (AI) in the ultrasound (US) diagnosis of breast cancer (BCa) is increasingly prevalent. However, the impact of US-probe frequencies on the diagnostic efficacy of AI models has not been clearly established.

Objectives: To explore the impact of using US-video of variable frequencies on the diagnostic efficacy of AI in breast US screening.

View Article and Find Full Text PDF

We propose and implement a high-bandwidth white-light visible light communication (VLC) system accomplishing data rate of 2.805 Gbit/s utilizing a semipolar blue micro-LED. The system uses an InGaN/GaN semipolar (20-21) blue micro-LED to excite yellow phosphor film for high-speed VLC.

View Article and Find Full Text PDF

Purpose: Attenuation imaging (ATI) is a new noninvasive ultrasound technique for assessing steatosis grade (S). However, validated region-of-interest (ROI) sampling strategies are not currently available. We investigated the diagnostic performance of various ATI-ROI positions for determining histopathologic S in patients with nonalcoholic fatty liver disease (NAFLD).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!