Contact replacement for NMR resonance assignment.

Bioinformatics

Department of Computer Science, Dartmouth College, Hanover, NH 03755, USA.

Published: July 2008

Motivation: Complementing its traditional role in structural studies of proteins, nuclear magnetic resonance (NMR) spectroscopy is playing an increasingly important role in functional studies. NMR dynamics experiments characterize motions involved in target recognition, ligand binding, etc., while NMR chemical shift perturbation experiments identify and localize protein-protein and protein-ligand interactions. The key bottleneck in these studies is to determine the backbone resonance assignment, which allows spectral peaks to be mapped to specific atoms. This article develops a novel approach to address that bottleneck, exploiting an available X-ray structure or homology model to assign the entire backbone from a set of relatively fast and cheap NMR experiments.

Results: We formulate contact replacement for resonance assignment as the problem of computing correspondences between a contact graph representing the structure and an NMR graph representing the data; the NMR graph is a significantly corrupted, ambiguous version of the contact graph. We first show that by combining connectivity and amino acid type information, and exploiting the random structure of the noise, one can provably determine unique correspondences in polynomial time with high probability, even in the presence of significant noise (a constant number of noisy edges per vertex). We then detail an efficient randomized algorithm and show that, over a variety of experimental and synthetic datasets, it is robust to typical levels of structural variation (1-2 AA), noise (250-600%) and missings (10-40%). Our algorithm achieves very good overall assignment accuracy, above 80% in alpha-helices, 70% in beta-sheets and 60% in loop regions.

Availability: Our contact replacement algorithm is implemented in platform-independent Python code. The software can be freely obtained for academic use by request from the authors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2718645PMC
http://dx.doi.org/10.1093/bioinformatics/btn167DOI Listing

Publication Analysis

Top Keywords

contact replacement
12
resonance assignment
12
contact graph
8
graph representing
8
nmr graph
8
nmr
7
contact
5
replacement nmr
4
resonance
4
nmr resonance
4

Similar Publications

Background: The application of international recommendations for paediatric maintenance haemodialysis (HD) could be strengthened by national laws or written recommendations. Our aim was therefore to describe the national rules governing paediatric maintenance HD in European countries.

Methods: A national representative, approved by the president of each paediatric nephrology society, was contacted in all 42 European countries to complete two online questionnaires.

View Article and Find Full Text PDF

During the blood coagulation cascade, coagulation factor VIII (FVIII) is activated by thrombin to form activated factor VIII (FVIIIa). FVIIIa associates with platelet surfaces at the site of vascular damage to form an intrinsic tenase complex with activated factor IX. A working model for FVIII membrane binding involves the association of positively charged FVIII residues with negatively charged lipid headgroups and the burial of hydrophobic residues into the membrane interior.

View Article and Find Full Text PDF

A cross-sectional study on improving clinical efficiency through centralized digital impression.

Hua Xi Kou Qiang Yi Xue Za Zhi

February 2025

Center of Stomatology, Peking University Shenzhen Hospital, Shenzhen 518036, China.

Objectives: This study aims to explore the effect of improving clinical efficiency by replacing traditional impression workflow with centralized digital impression workflow.

Methods: The department of prosthodontics in Center of Stomatology, Peking University Shenzhen Hospital has improved the clinical workflow by replacing the traditional impression made by doctors using impression materials for each patient with a centralized digital impression made by one technician for all patients in the department. This cross-sectional study recorded the chairside time required for impression taking in patients undergoing single posterior zirconia full crown restoration before clinical process improvement; the time required for centralized digital impression production; the comfort level of patients; and the adjacency relationship, occlusal contact relationship, and time required for prostheses adjusting (i.

View Article and Find Full Text PDF

Background: Reducing unnecessary emergency department (ED) visits following joint arthroplasty is an important goal. Literature suggests 30-day visit rates range between 4% and 15%, with only 20%-25% of these admitted for care. Low admissions suggest an opportunity to reduce unnecessary postarthroplasty ED visits.

View Article and Find Full Text PDF

The Internet has empowered millions of perpetrators who create and consume (CSAM), the current term replacing In this study, we coded data from a random sample of 2980 filenames from files shared in peer-to-peer (P2P) networks from U.S. IP addresses in 2021.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!