A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effects of ramelteon on respiration during sleep in subjects with moderate to severe chronic obstructive pulmonary disease. | LitMetric

Background: Individuals with moderate to severe chronic obstructive pulmonary disease (COPD) have poor sleep quality. This study evaluated the effects of ramelteon, an MT(1)/MT(2) melatonin receptor agonist indicated for insomnia treatment on respiration in this population.

Materials And Methods: This double-blind, crossover study enrolled 25 subjects (>or=40 years) with moderate to severe COPD (FEV(1)/FVC <70% and FEV(1) between 50 and 80% of predicted value [moderate], or FEV(1)/FVC <70% and FEV(1) <50% of predicted value [severe]). Subjects received ramelteon 8 mg or placebo for one night 30 min before polysomnographic monitoring, including measurement of oxygen saturation (SaO(2)) and respiratory effort and flow. Subjects crossed to alternate treatment after a 5- to 10-day washout. The primary endpoint was mean SaO(2) for the entire night.

Results: No significant difference in SaO(2) for the entire night was observed with ramelteon vs placebo (92.2% vs 92.5%, P = 0.576). Mean SaO(2) was similar between ramelteon and placebo for each hour of the night, each sleep stage, the number of minutes that SaO(2) was <80% and <90%, and mean apnea-hypopnea index. There was a significant difference in total sleep time (389.0 vs 348.4 min, P = 0.019) and sleep efficiency (81.0 vs 72.6%, P = 0.019), and latency to persistent sleep was shorter (23.1 vs 56.9 min, P = 0.051), with ramelteon vs placebo. All adverse events were mild to moderate; none led to study discontinuation.

Conclusion: Ramelteon did not produce respiratory depressant effects as measured by oxygenation or abnormal breathing events in subjects with moderate to severe COPD. Ramelteon was well tolerated in this population.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11325-008-0196-4DOI Listing

Publication Analysis

Top Keywords

moderate severe
12
effects ramelteon
8
severe chronic
8
chronic obstructive
8
obstructive pulmonary
8
pulmonary disease
8
ramelteon respiration
4
respiration sleep
4
sleep subjects
4
subjects moderate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!