Unlabelled: Drug-eluting stents (DES) are superior to bare metal stents in the prevention of restenosis and target lesion revascularization (TLR). This has led to a more aggressive use of DES in everyday interventional cardiology practice.

Methods: All consecutive patients who underwent coronary artery stenting with greater than 34 mm of overlapping, sirolimus-eluting stent (SES) were reviewed from a prospectively created database. A prespecified group of patients with greater than 60 mm of SES was also followed.

Results: 318 patients were followed up at a minimum of 6 months and a mean of 9 months. The mean target lesion stented length was over 55 mm. Use of IVUS was 19.8%. Forty patients (12.6%) suffered a peri-procedural CK-MB rise. The MACE rate at 9 months was 17% with 12.6% being periprocedural myocardial infarction (MI). Clinically driven TLR was 4.4% and cardiac death was 1.3%. There were 4 cases defined as late stent thrombosis. The independent predictors of periprocedural MI were the presence of a major side branch and longer target lesion stented length, with stable angina being a negative predictor. The independent predictors of in-stent restenosis were unstable angina and target lesion number per patient. There was a trend to increased MACE in the subgroup with longer than 60 mm of SES length.

Conclusion: The use of multiple, overlapping SES is safe and effective with an acceptably low follow up MACE rate. A significant peri-procedural CK-MB rise appears to be a risk of long segment stenting. Whether this translates to long-term sequelae needs further investigation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2008.02.012DOI Listing

Publication Analysis

Top Keywords

target lesion
16
multiple overlapping
8
overlapping sirolimus-eluting
8
coronary artery
8
consecutive patients
8
lesion stented
8
stented length
8
peri-procedural ck-mb
8
ck-mb rise
8
mace rate
8

Similar Publications

Background And Rationale: In-stent restenosis (ISR) remains the leading cause of treatment failure following percutaneous coronary intervention (PCI) with contemporary drug-eluting stents. Especially in small caliber coronary arteries, restenosis is common following PCI and represents a treatment challenge. Drug-coated balloons (DCB) are an attractive alternative to stents for treatment of both ISR and small vessel disease.

View Article and Find Full Text PDF

Stenosis within the arteriovenous fistula (AVF) of hemodialysis patients leads to vascular access dysfunction and inadequate hemodialysis. Percutaneous transluminal angioplasty (PTA) is the standard therapy for stenosis. However, rates of restenosis and loss of access patency remain high.

View Article and Find Full Text PDF

Unlabelled: Ultrasound imaging plays an important role in the early detection and management of breast cancer. This study aimed to evaluate the imaging performance of a range of clinically-used breast ultrasound systems using a set of novel spherical lesion contrast-detail (C-D) and anechoic-target (A-T) phantoms.

Methods: C-D and A-T phantoms were imaged using a range of clinical breast ultrasound systems and imaging modes.

View Article and Find Full Text PDF

Real-World 12-Month Outcomes with Sirolimus-Coated Balloon Angioplasty for Complex Femoropopliteal Disease.

J Clin Med

January 2025

Department of Vascular and Endovascular Surgery, Rhein Main Vascular Center, Asklepios Clinics Langen, Paulinen Wiesbaden, 63225 Langen, Germany.

: Sirolimus-coated balloons (SCBs) have emerged as a promising alternative to paclitaxel-coated devices for the treatment of femoropopliteal lesions. However, real-world data on SCB performance in also complex peripheral arterial disease remains unknown. We sought to evaluate the safety and 12-month clinical outcomes of the Selution SLR™ balloon angioplasty in a challenging real-world patient cohort.

View Article and Find Full Text PDF

: Multiparametric-Magnetic Resonance Imaging(mp-MRI) presents the ability to detect clinically significant cancer, aiming to avoid biopsy if the results are negative or target an abnormal lesion if a suspected lesion of the prostate is found. Recent guidelines recommend the performance of 12 standard biopsies along with 3 to 5 targeted biopsies in suspected prostate lesions, depending on the size of the prostate lesion. In addition, prostate biopsy can be performed by either the transperineal or the transrectal approach.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!