Burkholderia cepacia complex (Bcc) comprises nine closely related species or genomovars. It is an important causative agent of opportunistic infections and waterborne nosocomial infections. B. cepacia (formerly genomovar I) was identified from the blood culture of a baby in our neonatal unit (NU) in March 2005. B. cepacia was isolated four times from clinical specimens since the introduction of non-touch taps in the NU from 2000 to 2005 and only once from 1994 to 2000. Environmental samples were collected from the NU, including tap water from non-touch taps. Clinical and environmental isolates of Bcc were characterized using molecular identification and strain typing. A literature review was undertaken to delineate a method for eradication of Bcc. Several variations for hot water eradication of the organism from the taps were attempted. Genotyping and molecular analysis revealed that tap water isolates were B. cenocepacia which was a different species from the B. cepacia isolated from blood cultures of the neonate. However, B. cenocepacia has been known to cause nosocomial outbreaks and it was eventually eradicated from the NU by using repeated thermal shock (hot water at 65 degrees C for 10 min), changing taps and decolonizing sinks with hypochlorite. Molecular typing is useful in assisting the investigation of Bcc nosocomial infections.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1515/JPM.2008.038 | DOI Listing |
Infect Dis Health
February 2025
Infection Prevention and Epidemiology, Monash Health, Clayton Australia; Monash University, Clayton, Australia; South East Public Health Unit, Monash Health, Clayton, Australia.
Background: Burkholderia cenocepacia complex is an important cause of hospital acquired infections. We describe the management of an outbreak in a neonatal intensive care unit (NICU) due to tap colonisation.
Methods: Microbiological testing of touch (n = 26) and non-touch taps (n = 28), sinks and drains, including genomic sequencing of selected isolates.
Biofouling
May 2016
a Biosafety Investigation Unit , Public Health England , Salisbury , UK.
Hospital tap water is a recognised source of Pseudomonas aeruginosa. U.K.
View Article and Find Full Text PDFJ Hosp Infect
January 2014
Richard Wells Research Centre, University of West London, London, UK.
Background: Pseudomonas aeruginosa is an opportunistic pathogen with a particular propensity to cause disease in the immunocompromised. Water systems have been reported to contribute to P. aeruginosa transmission in healthcare settings.
View Article and Find Full Text PDFJ Perinat Med
October 2008
Southern Health-Monash Medical Centre, Clayton, Victoria, Australia.
J Hosp Infect
July 2005
Département de Microbiologie Médicale et Moléculaire, Unité de Bactériologie, EA 3854, UFR Médecine, Tours, France.
Non-touch taps, now common in hospitals, can easily be contaminated with Pseudomonas aeruginosa. We report our experience with 87 non-touch taps in a newly built wing of our teaching hospital contaminated with P. aeruginosa from the central pipe water system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!