A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrokinetically enhanced removal and degradation of nitrate in the subsurface using nanosized Pd/Fe slurry. | LitMetric

Electrokinetically enhanced removal and degradation of nitrate in the subsurface using nanosized Pd/Fe slurry.

J Environ Sci Health A Tox Hazard Subst Environ Eng

Institute of Environmental Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan.

Published: July 2008

The aim of this work was to evaluate the effectiveness of transporting the slurry of Pd/Fe bimetallic nanoparticles under an electric field in the subsurface for in situ removal and degradation of nitrate. To mimic the subsurface environment, a bench-scale horizontal column packed with nitrate-contaminated soil was treated by electrokinetic (EK) remediation coupled with the injection of nanosized Pd/Fe slurry. The estimated transport distance of Pd/Fe nanoparticles in soil based on the calculated sticking coefficient was about 9 meters by the enhancement of electrokinetics, primarily by electroosmotic (EO) flow. By injecting the nanosized Pd/Fe slurry into the anode reservoir coupled with the application of an electric field (i.e., Test 2) would result in the greatest overall removal efficiency of nitrate in soil and reservoir fluids as compared with other injection positions, the cathode reservoir being the worst injection spot. In Test 2, over 99% of nitrate in the whole system was removed and degraded even only 0.05 wt% of nanoscale Pd/Fe bimetal was injected.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10934520801974517DOI Listing

Publication Analysis

Top Keywords

nanosized pd/fe
12
pd/fe slurry
12
removal degradation
8
degradation nitrate
8
electric field
8
pd/fe
6
electrokinetically enhanced
4
enhanced removal
4
nitrate
4
nitrate subsurface
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!