The number of minimally invasive vascular interventions is increasing. In these interventions, a variety of devices are directed to and placed at the site of intervention. The device used in almost all of these interventions is the guidewire, acting as a monorail for all devices which are delivered to the intervention site. However, even with the guidewire in place, clinicians still experience difficulties during the interventions. As a first step toward understanding these difficulties and facilitating guidewire and device guidance, we have investigated the reproducibility of the final paths of the guidewire in vessel phantom models on different factors: user, materials and geometry. Three vessel phantoms (vessel diameters approximately 4 mm) were constructed having tortuousity similar to the internal carotid artery from silicon tubing and encased in Sylgard elastomer. Several trained users repeatedly passed two guidewires of different flexibility through the phantoms under pulsatile flow conditions. After the guidewire had been placed, rotational c-arm image sequences were acquired (9 in. II mode, 0.185 mm pixel size), and the phantom and guidewire were reconstructed (512(3), 0.288 mm voxel size). The reconstructed volumes were aligned. The centerlines of the guidewire and the phantom vessel were then determined using region-growing techniques. Guidewire paths appear similar across users but not across materials. The average root mean square difference of the repeated placement was 0.17 +/- 0.02 mm (plastic-coated guidewire), 0.73 +/- 0.55 mm (steel guidewire) and 1.15 +/- 0.65 mm (steel versus plastic-coated). For a given guidewire, these results indicate that the guidewire path is relatively reproducible in shape and position.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2673644PMC
http://dx.doi.org/10.1118/1.2903430DOI Listing

Publication Analysis

Top Keywords

guidewire
12
guidewire path
8
plastic-coated guidewire
8
evaluation guidewire
4
path reproducibility
4
reproducibility number
4
number minimally
4
minimally invasive
4
invasive vascular
4
interventions
4

Similar Publications

Purpose: Tibial valgus osteotomy has shown to be a successful and cost-effective procedure. The advent of image processing and three-dimensional (3D) printing is an interesting tool for achieving more accurate and reproducible results. The aim of our study was to compare the accuracy of the conventional technique and the use of customized guides in the correction of tibial deformities in tibial varus patients, the surgical and clinical benefits, and the impact of treatment in the outpatient setting.

View Article and Find Full Text PDF

The authors propose a modified transcatheter aortic valve replacement technique wherein the removal of the guidewire and delivery catheter immediately after the valve implantation helps to not only shorten the procedure but also decrease complications induced by the guidewire and delivery catheter.

View Article and Find Full Text PDF

Endoscopic ultrasound guided biliary drainage has become an effective drainage method for unresectable malignant obstructive jaundice, especially for patients after digestive tract reconstruction. We report a technique for assisting adequate guidewire biliary access during the drainage procedure.

View Article and Find Full Text PDF

We present the case of a 12-year-old girl with vesicoureteral reflux (VUR) of a solitary kidney treated using a modified hydrodistention implantation technique. A needle was set parallel to the ureteral guidewire inserted through the ureteral orifice before performing injections to correct VUR. Multi-site tandem injections were administered along the wire, which confirmed the direction and length of the ureteral tunnel.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!