A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Potential use of P-32 ophthalmic applicator: Monte Carlo simulations for design and dosimetry. | LitMetric

Postoperative beta-irradiation after pterygium excision has been considered a valuable therapeutic procedure to reduce the recurrence rate. Recently, it was reported that beta-irradiation also substantially reduced the risk of surgical failure after glaucoma surgery. Pure beta-irradiation using a 90Sr/Y applicator has been almost exclusively used for this purpose. As an alternative to 90Sr/Y beta-irradiation, we propose treatment with betas of a 32P source. While 32P has a lower maximum energy (1.71 MeV) than 90Sr/Y (2.27 MeV), it has an average energy comparable to that of 90Sr/Y. Furthermore, it can be produced easily in a nuclear reactor by neutron activation and is considered a less hazardous material. Monte Carlo simulations for the dosimetry of proposed 32P applicators were performed using the MCNP5 code. The structure and dimension of the 32P applicators were based on those of the 90Sr/Y applicators currently available, while medical plastic encapsulation and liquid source were chosen to enhance beta-dose to the surface of the conjunctiva. The 32P applicator showed that the surface dose distribution (up to 0.75 mm depth) is very similar to that of 90Sr/Y. However, beyond 0.75 mm depth, the 32P doses decrease with depths more rapidly than 90Sr/Y doses. In order to achieve the same surface dose rate, the required 32P activity is about three times that for a 90Sr/Y applicator. We conclude that the proposed 32P applicator can deliver therapeutic doses to the target lesion while sparing the lens better than the 90Sr/Y applicator. The 32P activity required to deliver therapeutic doses can be produced in a 30 MW reactor available at the Korea Atomic Energy Research Institute.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.2896076DOI Listing

Publication Analysis

Top Keywords

90sr/y applicator
12
90sr/y
9
32p
9
monte carlo
8
carlo simulations
8
proposed 32p
8
32p applicators
8
32p applicator
8
surface dose
8
075 depth
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!