Aims: To (1) correlate peak and maximum flow rates from non-instrumented flow (NIF) and pressure-flow studies (PFS) in women with pelvic organ prolapse (POP); (2) measure the impact of voided volume and degree of prolapse on correlations.

Methods: We compared four groups of women with stages II-IV POP. Groups 1 and 2 were symptomatically stress continent women participating in the colpopexy and urinary reduction efforts (CARE) trial; during prolapse reduction before sacrocolpopexy, Group 1 (n = 67) did not have and Group 2 (n = 84) had urodynamic stress incontinence (USI). Group 3 (n = 74) and Group 4 participants (n = 73), recruited specifically for this study, had stress urinary incontinence (SUI) symptoms. Group 3 planned sacrocolpopexy. Group 4 planned a different treatment option. Participants completed standardized uroflowmetry and pressure voiding studies.

Results: Subjects' median age was 61 years; median parity 3% and 80% had stage III or IV POP. Based on the Blaivas-Groutz nomogram, 49% of all women were obstructed. NIF and PFS peak and average flow rates had low correlations with one another (0.31, P < 0.001 and 0.35, P < 0.001, respectively). When NIF and PFS voided volumes were within 25% of each other, the peak and average flow rate correlations improved (0.52, P < 0.001 and 0.57, P < 0.001, respectively). As vaginal prolapse increased, correlations between NIF and PFS peak and average flow rates decreased.

Conclusion: Peak and average flow rates are highly dependent on voided volume in women with prolapse. As the prolapse stage increases, correlations between NIF and PFS variables decrease.

Download full-text PDF

Source
http://dx.doi.org/10.1002/nau.20568DOI Listing

Publication Analysis

Top Keywords

flow rates
16
nif pfs
16
peak average
16
average flow
16
pressure-flow studies
8
women pelvic
8
pelvic organ
8
organ prolapse
8
voided volume
8
sacrocolpopexy group
8

Similar Publications

Hypothesis: The porosity affects the rheological response of porous particle suspensions.

Experiments: Non-Brownian suspensions of porous particles immersed in a Newtonian Polyisobutene are investigated. Three different particles, with different porosity, pore structure and similar size, and non-porous irregular particles are used.

View Article and Find Full Text PDF

Introduction: Endoscopic Third Ventriculostomy (ETV) is a well-established treatment for pediatric hydrocephalus, particularly in cases of aqueductal stenosis. The ETV Success Score (ETVSS) is a predictive tool widely used to estimate the likelihood of ETV success based on factors like age. Its accuracy, especially in infants under 3 months, is still debated.

View Article and Find Full Text PDF

Feasibility and safety of ultra-low volume ventilation (≤ 3 ml/kg) combined with extra corporeal carbon dioxide removal (ECCOR) in acute respiratory failure patients.

Crit Care

December 2024

Department of Anesthesia and Intensive Care Unit, Regional University Hospital of Montpellier, St-Eloi Hospital, PhyMedExp, INSERM U1046, CNRS UMR, University of Montpellier, 9214, Montpellier Cedex 5, France.

Background: Ultra-protective ventilation is the combination of low airway pressures and tidal volume (Vt) combined with extra corporeal carbon dioxide removal (ECCOR). A recent large study showed no benefit of ultra-protective ventilation compared to standard ventilation in ARDS (Acute Respiratory Distress Syndrome) patients. However, the reduction in Vt failed to achieve the objective of less than or equal to 3 ml/kg predicted body weight (PBW).

View Article and Find Full Text PDF

Background: Identifying spontaneous circulation during cardiopulmonary resuscitation (CPR) is challenging. Current methods, which involve intermittent and time-consuming pulse checks, necessitate pauses in chest compressions. This issue is problematic in both in-hospital cardiac arrest and out-of-hospital cardiac arrest situations, where resources for identifying circulation during CPR may be limited.

View Article and Find Full Text PDF

Background: The stent-assisted coiling (SAC) and flow-diverter stent (FDS) techniques are widely used in the endovascular treatment of paraclinoid aneurysms. This article compares the occlusion rate, periprocedural complications, and clinical outcomes of SAC and FDSs.

Methods: Between January 2010 and December 2020, a systematic search of electronic databases identified 2283 articles for screening.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!