A new animal model for bone atrophic nonunion: fixation by external fixator.

J Orthop Res

Musculoskeletal Research Center Berlin, Center for Musculoskeletal Surgery, Charité, Universitätsmedizin Berlin, Free and Humboldt-University of Berlin, Augustenburger Platz 1, Forum 4, Psf. 24, D-13353 Berlin, Germany.

Published: December 2008

A new small animal model of bone atrophic nonunion was established for investigating the process of bone regeneration by performing cauterization of the periosteum, removal of the local bone marrow, and stabilization with external fixation. The model allows the creation of an atrophic nonunion without the need for a critical size defect. Furthermore, it provides reproducible, well-defined mechanical conditions and minimized physical interference of the implant with the biological processes in the healing zone. Eighty adult Sprague-Dawley rats received an osteotomy of the left femur, stabilized with an external fixator. In half of the animals, the periosteum proximal and distal to the osteotomy was destroyed by cauterization and the adjacent bone marrow was removed (nonunion group). At 2 and 8 weeks after surgery, radiological, biomechanical, histological, and histomorphometrical analyses showed a typical physiological healing in the control group, while the nonunion group was characterized by resorption of the bone ends with some callus formation distant to the osteotomy. At both time points, the callus was composed of significantly less bone and significantly more connective tissue (p < 0.001). In addition, the torsional strength of the osteotomized femur was significantly less in the nonunion group than in the control group, which was comparable to that of the intact femur (p < 0.001). In conclusion, the present model allows the induction of an atrophic nonunion without the need of a critical size defect. It is reproducible, provides standardized biomechanical conditions, and allows minimized interaction of the implant with the healing zone.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jor.20651DOI Listing

Publication Analysis

Top Keywords

atrophic nonunion
16
nonunion group
12
animal model
8
model bone
8
bone atrophic
8
external fixator
8
bone marrow
8
model allows
8
nonunion critical
8
critical size
8

Similar Publications

Case: A 14-year-old adolescent boy sustained a Gustilo-Anderson Type 3A tibia fracture treated with medullary nailing. He developed an atrophic nonunion with a 10.5-cm defect after debridement.

View Article and Find Full Text PDF

Aseptic nonunion is prevalent in orthopedic practice, causing persistent pain and functional impairment. Humeral shaft fractures, accounting for 3-5% of all fractures, have nonunion rates of 2-33% in nonoperative and 5-10% in surgical management. This study, the largest case series on operative management of humeral shaft nonunion, examines surgical techniques and outcomes.

View Article and Find Full Text PDF

Background: Bone transport in distraction osteogenesis is an effective, well-known procedure. However, bone compression is an aspect of this technique for which there is no objective information. The lack of direct bone compression measurements may result in a lack of uniformity in the bone transport process, which can result in its ineffective application and may be contributing to its underutilization.

View Article and Find Full Text PDF

A Case Series of Distal Radius and Ulna Nonunion Treated with Minimal Surgical Intervention.

J Wrist Surg

December 2024

Department of Orthopedic Surgery, Regional Rheumatoid and Degenerative Arthritis Center, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon, Republic of Korea.

 We hypothesized a treatment guideline for ulna/radius nonunion after failed surgical treatment and propose to verify it in a prospective study. Herein, we report our preliminary findings and review the current trend.  Six patients who met the criteria were retrospectively investigated, and we further categorized "nonunion of both the radius/ulna" into four subcategories.

View Article and Find Full Text PDF

Introduction: Critical-size bone defects in distal tibial open wounds pose a formidable challenge, requiring interventions that can address osseous reconstruction with less number of surgeries. Current treatment modalities may fall short in achieving optimal outcomes, with respect to early weight bearing due to the inability of the graft to sustain weight, graft-related infections, non-union in large defects, donor site morbidity, and non-availability of bone grafts due to earlier harvest. This case report explores the potential application of a 3D-printed mesh implant to this complex clinical scenario.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!