A poly(acrylic acid)-polyethylene graft copolymer was prepared and used initially to couple to acid phosphatase, using soluble carbodiimides. Yields which were quite good were obtained with CMC but not with EDAC. The copolymers was used to couple trypsin using EEDQ. Several organic solvents were investigated for the preparation of the "activated" poly(acrylic acid) intermediate. Using the activated system, high concentrations of trypsin were bound but the relative activities were not very high. The yield was good with bovine serum albumin (BSA). When the method was used for invertase, acid phosphatase, and alkaline phosphatase, the yields were poor and the copolymer was shown to absorb protein by an ion-exchange mechanism. However, the activated system gave a good yield of coupling to phenylpropylamine. A polyethylene-coacrylic-acid polymer containing 13% of acrylic acid (by weight) was then converted to the acid chloride by refluxing with thionyl chloride. The chlorinated copolymer which contained 0.7% chlorine and a thionyl-chloride-treated polyethylene control which contained no chlorine were investigated in immobilization studies. Such coupling involved bovine serum albumin (BSA), alkaline phosphatase, trypsin, beta-galactosidase, and invertase. Bovine serum albumin coupled well to the support, but none of the enzymes gave high levels of enzymes activity. Phenylpropylamine coupled well and all of the acid chloride groups were involved. Tyrosine reacted with 63% of the available acid chloride groups.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bit.260240610DOI Listing

Publication Analysis

Top Keywords

bovine serum
16
serum albumin
16
acid chloride
12
acid phosphatase
8
activated system
8
albumin bsa
8
alkaline phosphatase
8
coupled well
8
chloride groups
8
acid
7

Similar Publications

Label-free electrochemical immunosensors based on Cu-Ni metal-organic framework and carbon nanotube composite for carcinoembryonic antigen detection.

Bioelectrochemistry

January 2025

Hubei Key Laboratory of Diabetes and Angiopathy, Xianning 437100 PR China; School of Pharmacy, Hubei University of Science and Technology, Xianning 437100 PR China. Electronic address:

Monitoring cancer biomarkers is of great significance in clinical diagnosis. In this work, a label-free MWCNTs-COOH/CuNi-BTC/FTO electrochemical immunosensor was developed to quantitatively detect carcinoembryonic antigen (CEA). The bimetallic CuNi-BTC showed enhanced current than singe Ni-BTC, and the addition of the MWCNTs-COOH increased the conductivity and further amplified the current signal.

View Article and Find Full Text PDF

A novel ionic liquid MALDI matrix, 3-aminoquinoline/2',4',6'-trihydroxyacetophenone monohydrate (3-AQ/THAP), was developed for the rapid qualitative and quantitative detection of miRNA from biological samples. Compared to the traditional matrix 2,5-dihydroxybenzoic acid (DHB) and previously reported oligonucleotide-specific matrices, such as 3-aminopicolinic acid (3-APA), 3-hydroxypicolinic acid (3-HPA), and 6-aza-2-thiothymine (ATT), the 3-AQ/THAP matrix offers several advantages. It produces fewer alkali metal adduct peaks, exhibits higher sensitivity, and ensures better spot-to-spot repeatability.

View Article and Find Full Text PDF

An effective approach for the immobilization and protection of biological entities is their encapsulation via the in situ synthesis of metal-organic frameworks (MOFs). To ensure the preservation of the bioentities, mild synthetic conditions, including aqueous media and ambient conditions (temperature and pressure), are preferred. In this study, we investigated the synthesis of various aluminum polycarboxylate-based MOFs, including the fumarate, terephthalate, amino-terephthalate, and muconate forms of MIL-53(Al), as well as the MIL-110 and MIL-160 MOF types.

View Article and Find Full Text PDF

Methods based on enzyme labelling strategies have been widely developed for capacitance immunoassays, but most suffer from low sensitivity and are unfavorable for routine use in the early stages of diagnostics. Herein, we designed a highly efficient capacitance immunosensing method for the low-abundance neuroblastoma biomarker neuron-specific enolase (NSE) using an interdigitated micro-comb electrode. Initially, monoclonal mouse anti-human NSE capture antibodies were immobilized on the interdigitated gold electrodes using bovine serum albumin.

View Article and Find Full Text PDF

Autophagy activation within inflammatory microenvironment improved the therapeutic effect of MSC-Derived extracellular Vesicle in SLE.

J Adv Res

January 2025

Guangdong Provincial Key Laboratory of Autophagy and Major Chronic Non-communicable Diseases, Clinical Research and Experimental Center, Department of Nephrology, Affiliated Hospital of Guangdong Medical University, Zhanjiang 524000, China; Department of Clinical Laboratory, State Key Laboratory of Respiratory Disease, The First Affiliated Hospital of Guangzhou Medical University. Guangzhou 510120, China. Electronic address:

Introduction: Developing strategies to improve the therapeutic efficacy of mesenchymal stem cell (MSC)-derived extracellular vesicles (EVs) in autoimmune diseases have garnered increased attention.

Objectives: To evaluate whether rapamycin-induced autophagy within the systemic lupus erythematosus (SLE) inflammatory microenvironment (Rapa-SLE) augments the therapeutic effects of MSC-derived EVs in SLE.

Methods: The therapeutic potential of the resulting EVs (Rapa-SLE-EV) was assessed in MRL/lpr mice.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!