A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Failure causes, timing, and cluster behavior: an 8-year study of dental implants. | LitMetric

Objectives: The aim of this study was to analyze implant failure, causes, time of failure, and cluster behavior of implant failure among patients referred to a private surgical center.

Methods: All failed implants placed during the years 1997-2004 were analyzed. Data collected included age, gender, smoking habits, implant type and dimensions, timing of implantation (immediate or nonimmediate), time to failure, and failure causes.

Results: Overall, 99 of the 3609 implants placed between the years 1997 and 2004 failed in 61 patients resulting in a 97.3% survival rate. Patients with implant failure ranged in age from 21 to 78 years (average 54 years); 34% were men, 66% women; smoking was reported by 32.8%, pastsmoking 16.4%; time from implant placement to failure ranged from 1 to 99 months (average 24 months, SD = 24.8). Common causes for implant removal were bone loss and/or inflammation (52.5%), and implant mobility (43.4%). Cluster behavior (ie, more than one implant failure per patient, not necessarily in the same area or quadrant) was shown in one-third (32.8%) of the patients in which 56.6% of all failures were found. This cluster pattern was evident in both the surgical and prosthetic phase failures.

Conclusion: There is a higher probability for a cluster pattern among patients with implant failure. Common signs for failure are implant mobility (surgical phase) and infection and marginal bone loss (prosthetic phase).

Download full-text PDF

Source
http://dx.doi.org/10.1097/ID.0b013e3181777906DOI Listing

Publication Analysis

Top Keywords

implant failure
20
cluster behavior
12
failure
11
implant
10
time failure
8
behavior implant
8
implants years
8
patients implant
8
failure ranged
8
bone loss
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!