We study the effect of polarization and aperture geometry on the focal spot size of a high numerical aperture (NA) aplanatic lens. We show that for a clear aperture geometry, illuminating the lens by linear or circular polarization is preferable over radial polarization for spot size reduction applications. For annular aperture and objective lenses of 0.85 NA and above we give the sizes of the inner annulus which constitute the transition points to a state where the radial polarization illumination gives smaller spot size. We analyze the evolution, the profile and the effect of transverse and longitudinal field components in the focal plane, and show that they play an opposite role on the spot size in the cases of circular and radial polarization illumination. We show that in the limit of a very thin annulus the radial polarization approaches the prediction of the scalar theory at high NA, whereas the linear and circular polarizations deviate from it. We verify that the longitudinal component generated by radially polarized illumination produces the narrowest spot size for wide range of geometries. Finally, we discuss the effects of tight focusing on a dielectric interface and provide some ideas for circumventing the effects of the interface and even utilize them for spot size reduction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/oe.16.004567 | DOI Listing |
Biosensors (Basel)
November 2024
Institute of Laser Engineering, Osaka University, Suita 565-0871, Osaka, Japan.
Biosensors operating in the terahertz (THz) region are gaining substantial interest in biomedical analysis due to their significant potential for high-sensitivity trace-amount solution detection. However, progress in compact, high-sensitivity chips and methods for simple, rapid and trace-level measurements is limited by the spatial resolution of THz waves and their strong absorption in polar solvents. In this work, a compact nonlinear optical crystal (NLOC)-based reflective THz biosensor with a few arrays of asymmetrical meta-atoms was developed.
View Article and Find Full Text PDFVet Ophthalmol
December 2024
Koret School of Veterinary Medicine, The Hebrew University of Jerusalem, Rehovot, Israel.
Purpose: This study describes the ocular findings in dogs and cats diagnosed with Florida spot keratopathy (FSK) at a single institution.
Methods: Affected animals underwent a single comprehensive ophthalmic examination, with no follow-ups conducted. Data on patient demographics and clinical findings were collected and analyzed.
Int J Biol Macromol
December 2024
Department of Biotechnology, Faculty of Science, Mahidol University, Bangkok 10400, Thailand. Electronic address:
Delivering double-stranded RNA (dsRNA) in shrimp is challenging due to the lack of an effective carrier system. This study optimized chitosan nanoparticles (CNs) from two sources-α-chitosan from shrimp and β-chitosan from squid-to encapsulate antiviral dsRNA for oral administration via shrimp feed. Using response surface methodology (RSM), formulations were refined for encapsulation efficiency, particle size, polydispersity index, and zeta potential.
View Article and Find Full Text PDFJ Synchrotron Radiat
January 2025
Institute Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Straße 15, 12489 Berlin, Germany.
Resonant inelastic X-ray scattering (RIXS) is an ideal X-ray spectroscopy method to push the combination of energy and time resolutions to the Fourier transform ultimate limit, because it is unaffected by the core-hole lifetime energy broadening. Also, in pump-probe experiments the interaction time is made very short by the same core-hole lifetime. RIXS is very photon hungry so it takes great advantage from high-repetition-rate pulsed X-ray sources like the European XFEL.
View Article and Find Full Text PDFMed Phys
December 2024
Research Center for Advanced Detection Materials and Medical Imaging Devices, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China.
Background: The complementary absorption contrast CT (ACT) and differential phase contrast CT (DPCT) can be generated simultaneously from an x-ray computed tomography (CT) imaging system incorporated with grating interferometer. However, it has been reported that ACT images exhibit better spatial resolution than DPCT images. By far, the primary cause of such discrepancy remains unclear.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!