Assessing local tissue water using tissue dielectric constant (TDC) values is useful to evaluate oedema/lymphoedema features and their change. Knowledge of anatomical site and tissue depth dependence of TDC values could extend this method's utility. Our goal was to compare TDC values obtained at anatomically paired sites and to investigate their depth dependence. In 22 women (12 awaiting surgery for breast cancer and 10 cancer-free control subjects), four sites (mid-forearm, mid-biceps, axilla and lateral thorax) on both body sides were measured with a 2.5-mm sampling depth probe. Also, at forearm, four different probes with sampling depths of 0.5, 1.5, 2.5 and 5 mm were used. TDC values range between 1 for zero water to 78.5 for 100% water. Site comparisons showed TDC values (mean+/-SD) to be largest at axilla (36.4+/-8.9), least at biceps (21.6+/-3.5) and not different between forearm and thorax (24.3+/-4.0 versus 24.8+/-5.0). Group comparisons showed slightly greater values in patients at forearm and biceps (P<0.05) but no group difference at other sites. Dominant-non-dominant side comparisons showed no significant difference in paired-TDC values in either group at any site. Forearm TDC values decreased with increasing depth from 36.4+/-4.8 at 0.5 mm to a minimum of 21.4+/-3.9 at 5.0 mm, with a sharp decline between 1.5 and 2.5 mm. The composite findings suggest that TDC measurements have the necessary features for usefully assessing oedema/lymphoedema and its change on limbs and at body sites not routinely amenable to assessment by other techniques. The depth dependence feature provides additional flexibility to investigate oedematous or lymphoedematous conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1475-097X.2008.00814.xDOI Listing

Publication Analysis

Top Keywords

tdc values
20
depth dependence
12
local tissue
8
tissue water
8
tissue dielectric
8
dielectric constant
8
anatomical site
8
dependence women
8
breast cancer
8
values
6

Similar Publications

Cephalometric analysis is the primary diagnosis method in orthodontics. In our previous study, the algorithm was developed to estimate cephalometric landmarks from lateral facial photographs of patients with normal occlusion. This study evaluates the estimation accuracy by the algorithm trained on a dataset of 2320 patients with added malocclusion patients and the analysis values.

View Article and Find Full Text PDF

Purpose: To complement the current research on altered white matter integrity in children with non-lesional temporal lobe epilepsy (NL-TLE), especially the correlation between diffusion metrics and clinical characteristics, so as to provide imaging evidence for clinical practice.

Methods: Children with temporal lobe epilepsy and no lesions on magnetic resonance imaging (MRI) were retrospectively collected from 2016.01.

View Article and Find Full Text PDF

Assessing Tissue Dielectric Constant Values in Tumor Bearing and Healthy Breasts.

Lymphat Res Biol

December 2024

Gentle Touch Breast Diagnostics, Coral Springs, Florida, USA.

This study aimed to investigate, characterize, and provide quantitative reference data on tissue dielectric constant (TDC) values of female breasts when measurements were made to 5 mm depths and determine the utility of these measurements to differentiate between benign and malignant breast tumors. Breast TDC was measured bilaterally in 82 women just prior to an ultrasound-guided diagnostic biopsy of one tumor in one breast. TDC was measured in triplicate over the tumor and the contralateral healthy breast.

View Article and Find Full Text PDF

Health Economic Evaluation of Antimicrobial Stewardship, Procalcitonin Testing, and Rapid Blood Culture Identification in Sepsis Care: A 90-Day Model-Based, Cost-Utility Analysis.

Pharmacoecon Open

January 2025

Department of Critical Care Medicine, Faculty of Medicine and Dentistry, University of Alberta and Alberta Health Services, 2-124 Clinical Sciences Building, 8440 112 Street NW, Edmonton, Alberta, T6G 2B7, Canada.

Objective: We evaluated the cost-effectiveness of a bundled intervention including an antimicrobial stewardship program (ASP), procalcitonin (PCT) testing, and rapid blood culture identification (BCID), compared with pre-implementation standard care in critically ill adult patients with sepsis.

Methods: We conducted a decision tree model-based cost-effectiveness analysis alongside a previously published pre- and post-implementation quality improvement study. We adopted a public Canadian healthcare payer's perspective.

View Article and Find Full Text PDF

Skin tissue dielectric constant: Time of day and skin depth dependence.

Clin Physiol Funct Imaging

January 2025

Department of Medical Education, Dr. Kiran C. Patel College of Allopathic Medicine, Nova Southeastern University, Fort Lauderdale, Florida, USA.

Background: Skin water measurements are used to investigate skin physiology, clinically study dermatological issues, and for conditions like diabetes, oedema, and lymphedema with measurements done at various times of day (TOD). One method used is skin's tissue dielectric constant (TDC), often clinically measured to a single depth of 2.5 mm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!