The purpose of this research was to investigate the torque capacity of active and passive self-ligating brackets compared with metallic, ceramic, and polycarbonate edgewise brackets. Six types of orthodontic brackets were included in the study: the self-ligating Speed and Damon2, the stainless steel (SS), Ultratrimm and Discovery, the ceramic bracket, Fascination 2, and the polycarbonate bracket, Brillant. All brackets had a 0.022-inch slot size and were torqued with 0.019 x 0.025-inch SS archwires. For this purpose, the labial crown torque of an upper central incisor was measured in a simulated intraoral clinical situation using the orthodontic measurement and simulation system (OMSS). A torque of 20 degrees was applied and the correction of the misalignement was simulated experimentally with the OMSS. Each bracket/wire combination was measured five times. Maximum torquing moments and torque loss were determined. The results were analysed with one-way analysis of variance, with the bracket serving as the sole discriminating variable, and the Tukey test at the 0.05 level of significance. The ceramic bracket (Fascination 2) presented the highest torquing moment (35 Nmm) and, together with a SS bracket, the lowest torque loss (4.6 degrees). Self-ligating, polycarbonate, and selective metallic brackets demonstrated almost a 7-fold decreased moment developed during insertion of a 0.019 x 0.022-inch SS wire into a 0.022-inch slot and a 100 per cent increase in loss.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ejo/cjn005 | DOI Listing |
Korean J Orthod
January 2025
Materials Research Institute, National Autonomous University of Mexico, Mexico City, Mexico.
Objective: To study the influence of bracket base meshes on shear bond strength and observe them using a scanning electron microscopy (SEM) before and after debonding.
Methods: Ninety brackets were divided into nine groups of 10 samples each: G1-Alexander, G2-Mini Sprint Brackets, G3-In-Ovation R CCO, G4-Gemini SL Self-Ligating Bracket, G5-Classic mini 2G Stylus, G6-Gemini Metal Brackets, G7-Clarity Advanced, G8-Crystall-Ize, and G9-Ceramic Series Flexx 2G. Groups G1 to G6 and G7 to G9 consisted of metallic and aesthetic brackets, respectively.
BMC Oral Health
January 2025
Department of Stomatology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510080, China.
Background: Proper torque control is crucial to the outcome of orthodontic treatment. This study aimed to employ finite element analysis to compare the torque capabilities of a novel spherical self-ligating bracket with a lock-hook system against those of commonly used passive self-ligating and conventional bracket systems, as well as to reveal the biomechanical changes in the periodontal ligament (PDL) during torque expression.
Methods: A maxillary right central incisor, along with its PDL and alveolar bone, were modeled.
J Clin Exp Dent
November 2024
D.D.S., M.Sc., Ph.D. Professor. Department of Orthodontics. Bauru Dental School, University of São Paulo, Brazil.
Background: We aimed to evaluate changes in buccal bone thickness (BBT), buccolingual dental inclinations (BLI), and transversal widths (TW) after treatment using a passive self-ligating system.
Material And Methods: Pre- and posttreatment cone-beam computed tomography images (CBCT) of 21 Class I patients (initial mean age: 14.99 ± 1.
Saudi Dent J
November 2024
Department of Clinical Sciences, Center of Medical and Bio-Allied Health Sciences Research, College of Dentistry, Ajman University, Ajman, United Arab Emirates.
Objective: The objective of this study was to compare the microbial adhesion of different oral pathogens on different wires used in orthodontic treatment and to evaluate the potential of these pathogens to form biofilms on different types of orthodontic wires and brackets.
Methods: In this in vitro investigation, we calculated that the sample size for each group (i.e.
Cureus
October 2024
Department of Orthodontics and Dentofacial Orthopedics, Kothiwal Dental College and Research Centre, Moradabad, IND.
Introduction: This study aimed to perform a comparative analysis of stresses and displacements with incremental torque on the maxillary incisors and surrounding cortical bone using conventional metal brackets with rectangular slots and passive self-ligating brackets with square slots using finite element analysis (FEA).
Materials And Methods: An in vitro FEA study was conducted, in which a three-dimensional (3D) model of the maxilla was built using ANSYS software version 18 (ANSYS Inc., Canonsburg, PA).