Removal of gadolinium by peritoneal dialysis.

Clin Nephrol

Renal Electrolyte and Hypertension Division, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA.

Published: May 2008

An association between gadolinium-containing contrast and the development of nephrogenic systemic fibrosis (NSF) has been increasingly recognized. For patients receiving hemodialysis (HD) who are exposed to gadolinium, the Federal Drug Administration (FDA) recommends HD to remove this contrast agent in order to minimize the risk of NSF. This study examines if gadolinium can be removed by frequent exchanges by peritoneal dialysis (PD). Following administration of 0.1 mmol/kg of gadodiamide to a patient with end-stage renal disease, the serum clearance of this contrast agent by automated PD was examined. 10 and 15 exchanges of PD using an automated cycler were respectively performed during the first and second 24-hour periods after gadolinium exposure. Serum gadolinium levels were measured 1 hour after the gadolinium administration, then at 24 and 48 hours after PD was initiated. 90% of the gadolinium was removed from the circulation in 2 days with a regimen of 10-15 exchanges per day of PD. For patients on chronic maintenance PD who receive gadolinium, our case suggests that a temporary intensive automated PD regimen, aimed at maximizing clearance of this contrast agent immediately after exposure, could be an effective alternative when institution of HD is problematic.

Download full-text PDF

Source
http://dx.doi.org/10.5414/cnp69368DOI Listing

Publication Analysis

Top Keywords

contrast agent
12
peritoneal dialysis
8
gadolinium removed
8
clearance contrast
8
gadolinium
7
removal gadolinium
4
gadolinium peritoneal
4
dialysis association
4
association gadolinium-containing
4
contrast
4

Similar Publications

Background: Subarachnoid hemorrhage (SAH) is associated with significant mortality and morbidity. The impact of SAH on human glymphatic function remains unknown.

Methods: This prospective, controlled study investigated whether human glymphatic function is altered after SAH, how it differs over time, and possible underlying mechanisms.

View Article and Find Full Text PDF

Multiparametric MRI for Assessment of the Biological Invasiveness and Prognosis of Pancreatic Ductal Adenocarcinoma in the Era of Artificial Intelligence.

J Magn Reson Imaging

January 2025

Nurturing Center of Jiangsu Province for State Laboratory of AI Imaging & Interventional Radiology, Department of Radiology, Zhongda Hospital, Medical School of Southeast University, Nanjing, China.

Pancreatic ductal adenocarcinoma (PDAC) is the deadliest malignant tumor, with a grim 5-year overall survival rate of about 12%. As its incidence and mortality rates rise, it is likely to become the second-leading cause of cancer-related death. The radiological assessment determined the stage and management of PDAC.

View Article and Find Full Text PDF

Background: Growth differentiation factor 15 (GDF-15) is a robust prognostic biomarker in patients with cardiovascular (CV) disease, and a better understanding of its clinical determinants is desirable. We aimed to study the associations between GDF-15 levels and in outpatients with peripheral arterial disease (PAD).

Methods: An explorative cross-sectional study (Study of Atherosclerosis in Vastmanland, Västerås, Sweden) included 439 outpatients with carotid or lower extremity PAD.

View Article and Find Full Text PDF

Objective: To evaluate the clinical efficacy of ultrafast dynamic contrast-enhanced (DCE)-MRI using a compressed sensing (CS) technique for differentiating benign and malignant soft-tissue tumors (STTs) and to evaluate the factors related to the grading of malignant STTs.

Materials And Methods: A total of 165 patients (96 male; mean age, 61 years), comprising 111 with malignant STTs and 54 with benign STTs according to the 2020 WHO classification, underwent DCE-MRI with CS between June 2018 and June 2023. The clinical, qualitative, and quantitative parameters associated with conventional MRI were also obtained.

View Article and Find Full Text PDF

This study aimed to develop a Least Absolute Shrinkage and Selection Operator (LASSO) logistic regression (LR) model using quantitative imaging features from Shear Wave Elastography (SWE) and Contrast-Enhanced Ultrasound (CEUS) to assess the malignancy risk of BI-RADS 4 breast lesions (BLs). The features predictive of malignancy in the LASSO analysis were used to construct a nomogram. Female patients (n = 111) with BI-RADS 4 BLs detected via routine ultrasound at Ma'anshan People's Hospital underwent SWE, CEUS, and histopathological examinations were enrolled in this study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!