Purpose: To present a method for the dosimetric analysis of permanent prostate brachytherapy implants using a combination of stereoscopic X-ray radiography and magnetic resonance (MR) imaging (XMR) in an XMR facility, and to compare the clinical results between XMR- and computed tomography (CT)-based dosimetry.
Methods And Materials: Patients who had received nonstranded iodine-125 permanent prostate brachytherapy implants underwent XMR and CT imaging 4 weeks later. Four observers outlined the prostate gland on both sets of images. Dose-volume histograms (DVHs) were derived, and agreement was compared among the observers and between the modalities.
Results: A total of 30 patients were evaluated. Inherent XMR registration based on prior calibration and optical tracking required a further automatic seed registration step that revealed a median root mean square registration error of 4.2 mm (range, 1.6-11.4). The observers agreed significantly more closely on prostate base and apex positions as well as outlining contours on the MR images than on those from CT. Coefficients of variation were significantly higher for observed prostate volumes, D90, and V100 parameters on CT-based dosimetry as opposed to XMR. The XMR-based dosimetry showed little agreement with that from CT for all observers, with D90 95% limits of agreement ranges of 65, 118, 79, and 73 Gy for Observers 1, 2, 3, and 4, respectively.
Conclusions: The study results showed that XMR-based dosimetry offers an alternative to other imaging modalities and registration methods with the advantages of MR-based prostate delineation and confident three-dimensional reconstruction of the implant. The XMR-derived dose-volume histograms differ from the CT-derived values and demonstrate less interobserver variability.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijrobp.2008.03.065 | DOI Listing |
Brachytherapy
November 2024
Carleton Laboratory for Radiotherapy Physics, Physics Department, Carleton University, Ottawa, Ontario, Canada. Electronic address:
Purpose: Demonstrate quantitative characterization of 3D patient-specific absorbed dose distributions using Haralick texture analysis, and interpret measures in terms of underlying physics and radiation dosimetry.
Methods: Retrospective analysis is performed for 137 patients who underwent permanent implant prostate brachytherapy using two simulation conditions: "TG186" (realistic tissues including 0-3.8% intraprostatic calcifications; interseed attenuation) and "TG43" (water-model; no interseed attenuation).
J Sex Med
January 2025
Sexual & Reproductive Medicine Program, Department of Surgery, Urology Service, Memorial Sloan Kettering Cancer Center, New York, NY 10065, United States.
J Radiat Res
December 2024
Department of Radiology, University of Yamanashi Faculty of Medicine, 1110 Shimokato, Chuo-shi, Yamanashi 409-3898, Japan.
Curr Urol Rep
October 2024
Department of Urology, Northwell Health, Manhasset, NY, USA.
Purpose Of Review: The prevalence of benign prostatic hyperplasia (BPH) is rising, however, current treatment options present severe complications and limit patient's quality of life. Accordingly, advancements in prostatic catheter and stent designs for use in treating lower urinary tract symptoms (LUTS) in BPH patients have largely expanded in the past five years and we aim to provide an exhaustive summary of recent outcomes.
Recent Findings: The dual dilation and paxlitaxel eluting Optilume BPH Catheter System enhances promise in catheter-based treatments, providing the longest sustained increase in max urinary flow rate and decrease in post-void residual volume compared to alternative MISTs.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!