Purpose: To present a method for the dosimetric analysis of permanent prostate brachytherapy implants using a combination of stereoscopic X-ray radiography and magnetic resonance (MR) imaging (XMR) in an XMR facility, and to compare the clinical results between XMR- and computed tomography (CT)-based dosimetry.

Methods And Materials: Patients who had received nonstranded iodine-125 permanent prostate brachytherapy implants underwent XMR and CT imaging 4 weeks later. Four observers outlined the prostate gland on both sets of images. Dose-volume histograms (DVHs) were derived, and agreement was compared among the observers and between the modalities.

Results: A total of 30 patients were evaluated. Inherent XMR registration based on prior calibration and optical tracking required a further automatic seed registration step that revealed a median root mean square registration error of 4.2 mm (range, 1.6-11.4). The observers agreed significantly more closely on prostate base and apex positions as well as outlining contours on the MR images than on those from CT. Coefficients of variation were significantly higher for observed prostate volumes, D90, and V100 parameters on CT-based dosimetry as opposed to XMR. The XMR-based dosimetry showed little agreement with that from CT for all observers, with D90 95% limits of agreement ranges of 65, 118, 79, and 73 Gy for Observers 1, 2, 3, and 4, respectively.

Conclusions: The study results showed that XMR-based dosimetry offers an alternative to other imaging modalities and registration methods with the advantages of MR-based prostate delineation and confident three-dimensional reconstruction of the implant. The XMR-derived dose-volume histograms differ from the CT-derived values and demonstrate less interobserver variability.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijrobp.2008.03.065DOI Listing

Publication Analysis

Top Keywords

permanent prostate
12
prostate brachytherapy
12
brachytherapy implants
12
x-ray radiography
8
radiography magnetic
8
magnetic resonance
8
dose-volume histograms
8
xmr-based dosimetry
8
prostate
7
xmr
6

Similar Publications

Haralick texture feature analysis for Monte Carlo dose distributions of permanent implant prostate brachytherapy.

Brachytherapy

November 2024

Carleton Laboratory for Radiotherapy Physics, Physics Department, Carleton University, Ottawa, Ontario, Canada. Electronic address:

Purpose: Demonstrate quantitative characterization of 3D patient-specific absorbed dose distributions using Haralick texture analysis, and interpret measures in terms of underlying physics and radiation dosimetry.

Methods: Retrospective analysis is performed for 137 patients who underwent permanent implant prostate brachytherapy using two simulation conditions: "TG186" (realistic tissues including 0-3.8% intraprostatic calcifications; interseed attenuation) and "TG43" (water-model; no interseed attenuation).

View Article and Find Full Text PDF

Predictors of corporo-venocclusive dysfunction in men with bilateral nerve-sparing radical prostatectomy.

J Sex Med

January 2025

Sexual & Reproductive Medicine Program, Department of Surgery, Urology Service, Memorial Sloan Kettering Cancer Center, New York, NY 10065, United States.

Article Synopsis
  • Erectile dysfunction (ED) can occur in men who have had bilateral nerve-sparing surgery, with corporo-venocclusive dysfunction (CVOD) being a primary cause of permanent ED after radical prostatectomy (RP).
  • A study examined comorbidity factors linked to CVOD in men without prior ED who underwent RP, finding significant associations with increased age and obstructive sleep apnea (OSA).
  • The research highlights that comorbidities, particularly OSA, influence recovery of erectile function post-surgery; however, the findings may not apply broadly to all patients, as the study focused on men already seeking treatment for ED.
View Article and Find Full Text PDF
Article Synopsis
  • Brachytherapy (BT), particularly high dose rate (HDR) BT, has become more complex due to advanced techniques, necessitating significant training for radiotherapy technologists and medical physicists (RTMPs).
  • A survey conducted across 837 radiation treatment facilities in Japan revealed varying working times for HDR procedures and low quality control (QC) implementation rates for BT compared to external beam radiation therapy (EBRT).
  • The findings underscore a need for improved training and education for RTMPs to enhance the quality and safety of BT practices in Japan.
View Article and Find Full Text PDF

Purpose Of Review: The prevalence of benign prostatic hyperplasia (BPH) is rising, however, current treatment options present severe complications and limit patient's quality of life. Accordingly, advancements in prostatic catheter and stent designs for use in treating lower urinary tract symptoms (LUTS) in BPH patients have largely expanded in the past five years and we aim to provide an exhaustive summary of recent outcomes.

Recent Findings: The dual dilation and paxlitaxel eluting Optilume BPH Catheter System enhances promise in catheter-based treatments, providing the longest sustained increase in max urinary flow rate and decrease in post-void residual volume compared to alternative MISTs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!