A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cumulative patient effective dose in cardiology. | LitMetric

Medical radiation from X-rays and nuclear medicine is the largest non-natural (man-made) source of radiation exposure in Western countries. The aim of this study was to assess the individual cumulative effective dose in patients admitted to our cardiology ward. We collected a cumulative radiological history from a structured questionnaire and access to hospital records in 50 consecutive adult patients (36 males; age, 66.7+/-10.8 years) admitted to the Institute of Clinical Physiology in Pisa. The cumulative effective dose was assessed as an indicator of stochastic risk of cancer. We derived the effective dose for each individual examination from the Medical Imaging Guidelines of the European Commission (2001). On average, each patient underwent a median of 36 examinations (interquartile range, 23-46). The median cumulative effective dose was 60.6 mSv. Three types of procedures were responsible for approximately 86% of the total collective effective dose: (i) arteriography and interventional cardiology (12% of examinations, 48% of average dose per patient); (ii) nuclear medicine (5% of examinations, 21% of average dose per patient); and (iii) CT (4% of examinations, 17% of average dose per patient). The median estimated extra risk of cancer was approximately 1 in 200 exposed subjects. In conclusion, the average contemporary cardiological patient is exposed to a significant cumulative effective dose from diagnostic and therapeutic interventions. It is important to log cumulative dose for each patient at the time of each examination. Every effort should be made to justify the indications and to optimize the doses.

Download full-text PDF

Source
http://dx.doi.org/10.1259/bjr/29507259DOI Listing

Publication Analysis

Top Keywords

effective dose
28
cumulative effective
16
dose patient
16
average dose
12
dose
11
nuclear medicine
8
risk cancer
8
cumulative
7
effective
7
patient
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!