Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A highly sensitive inductively coupled plasma mass spectrometry (ICP-MS) method with microwave-assisted sample digestion for the determination of total platinum in rat whole and ultrafiltrate plasma was developed and validated. A first step of this study concerned the optimization of the mineralization procedure, in order to obtain good extraction recovery (higher than 90%) and repeatability (less than 6%) and the absence of matrix effect. ICP-MS analysis was then performed using the "hot plasma/protective ion extraction" mode, achieving high sensitivity and very high signal/noise ratio. Iridium was added as internal standard. The method was then submitted to validation, performed according to the FDA Bioanalytical Validation Methods guidelines and to the Eurachem guide. Validation was carried out in terms of limit of detection (LOD), limit of quantitation (LOQ), linearity, precision, accuracy and stability. An instrumental LOQ of 1.9ngL(-1), corresponding to a concentration of 955ngL(-1) in matrix under the adopted conditions, was obtained, allowing the quantitative analysis of Pt ultratraces. Instrumental linearity was verified in the range 1.9-14,000ngL(-1), corresponding to a concentration range from 955ngL(-1) to 6825microgL(-1) in matrix. Accuracy was evaluated by analyzing control samples for both matrices at different concentration levels; a good agreement (<15%) was obtained. Sample stability was tested by analyzing control samples maintained for 4h at room temperature or submitted to three freezing-thawing cycles. Finally, the developed method was applied to the analysis of plasma and ultrafiltrate plasma of rats treated with oxaliplatin-base drug, thus demonstrating its reliability in pharmacokinetic studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpba.2008.04.013 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!