Context: Based on concerns about the risk of infection, the jugular site is often preferred over the femoral site for short-term dialysis vascular access.

Objective: To determine whether jugular catheterization decreases the risk of nosocomial complications compared with femoral catheterization.

Design, Setting, And Patients: A concealed, randomized, multicenter, evaluator-blinded, parallel-group trial (the Cathedia Study) of 750 patients from a network of 9 tertiary care university medical centers and 3 general hospitals in France conducted between May 2004 and May 2007. The severely ill, bed-bound adults had a body mass index (BMI) of less than 45 and required a first catheter insertion for renal replacement therapy.

Intervention: Patients were randomized to receive jugular or femoral vein catheterization by operators experienced in placement at both sites.

Main Outcome Measures: Rates of infectious complications, defined as catheter colonization on removal (primary end point), and catheter-related bloodstream infection.

Results: Patient and catheter characteristics, including duration of catheterization, were similar in both groups. More hematomas occurred in the jugular group than in the femoral group (13/366 patients [3.6%] vs 4/370 patients [1.1%], respectively; P = .03). The risk of catheter colonization at removal did not differ significantly between the femoral and jugular groups (incidence of 40.8 vs 35.7 per 1000 catheter-days; hazard ratio [HR], 0.85; 95% confidence interval [CI], 0.62-1.16; P = .31). A prespecified subgroup analysis demonstrated significant qualitative heterogeneity by BMI (P for the interaction term < .001). Jugular catheterization significantly increased incidence of catheter colonization vs femoral catheterization (45.4 vs 23.7 per 1000 catheter-days; HR, 2.10; 95% CI, 1.13-3.91; P = .017) in the lowest tercile (BMI <24.2), whereas jugular catheterization significantly decreased this incidence (24.5 vs 50.9 per 1000 catheter-days; HR, 0.40; 95% CI, 0.23-0.69; P < .001) in the highest tercile (BMI >28.4). The rate of catheter-related bloodstream infection was similar in both groups (2.3 vs 1.5 per 1000 catheter-days, respectively; P = .42).

Conclusion: Jugular venous catheterization access does not appear to reduce the risk of infection compared with femoral access, except among adults with a high BMI, and may have a higher risk of hematoma.

Trial Registration: clinicaltrials.gov Identifier: NCT00277888.

Download full-text PDF

Source
http://dx.doi.org/10.1001/jama.299.20.2413DOI Listing

Publication Analysis

Top Keywords

catheter colonization
12
1000 catheter-days
12
femoral
8
femoral jugular
8
jugular venous
8
venous catheterization
8
risk nosocomial
8
renal replacement
8
risk infection
8
jugular catheterization
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!