Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Prediction of left ventricular functional recovery is important after myocardial infarction. The impact of quantitative perfusion and motion analyses with gated single-photon emission computed tomography (SPECT) on predictive ability has not been clearly defined in multi-center studies.
Methods: A total of 252 patients with recent myocardial infarction (n = 74) and old myocardial infarction (n = 175) were registered from 25 institutions. All patients underwent resting gated SPECT using (99m)Tc-hexakis-2-methoxy-isobutyl isonitrile (MIBI) and repeated the study after revascularization after an average follow-up period of 132 +/- 81 days. Visual and quantitative assessment of perfusion and wall motion were performed in 5,040 segments.
Results: Non-gated segmental percent uptake and end-systolic (ES) percent uptake were good predictors of wall motion recovery and significantly differed between improved and non-improved groups (66 +/- 17% and 55 +/- 18%, p < 0.0001 for non-gated; 64 +/- 16% and 51 +/- 17% for ES percent uptake, p < 0.0001). The area under the curve of receiver operating characteristics curve for non-gated percent uptake, ES percent uptake, end-diastolic percent uptake and visual perfusion defect score was 0.70, 0.71, 0.61, and 0.56, respectively. Sensitivity and specificity of percent uptake were 68% and 64% for non-gated map and 80% and 52% for ES percent uptake map. An optimal threshold for predicting segmental improvement was 63% for non-gated and 52% for ES percent uptake values.
Conclusion: Segmental (99m)Tc-MIBI uptake provided a useful predictor of wall motion improvement. Application of quantitative approach with non-gated and ES percent uptake enhanced predictive accuracy over visual analysis particularly in a multi-center study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00259-008-0838-6 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!