A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cardiac output monitoring: comparison of a new arterial pressure waveform analysis to the bolus thermodilution technique in patients undergoing off-pump coronary artery bypass surgery. | LitMetric

Objective: To analyze the clinical agreement between the conventional intermittent bolus thermodilution (TD) technique and a new arterial pressure waveform analysis (APCO) technique (FloTrac; Edward Lifesciences, Irvine, CA) for cardiac output (CO) estimation.

Design: Prospective observational clinical study.

Setting: Cardiac surgery operating room of a tertiary care cardiac center.

Participants: Twelve patients undergoing elective off-pump coronary artery bypass (OPCAB) surgery.

Measurements And Main Results: CO was determined by 2 different methods: TD and APCO at 8 time points (preinduction, postinduction, poststernotomy, left internal mammary artery to left anterior descending artery anastomosis, left [obtuse marginal/diagonal] anastomosis, right [right coronary/posterior descending coronary artery] anastomosis, postprotamine administration, and poststernal closure) in 12 patients undergoing elective OPCAB surgery. The mean bias and limits of agreement (2 standard deviations) expressed in liters per minute at respective points of measurement were -0.54 +/- 1.12, -0.37 +/- 1.0, -0.42 +/- 1.50, -0.25 +/- 1.18, -0.31 + 1.28, +/-0.41 +/- 1.0, 0.06 +/- 1.50, and 0.09 +/- 1.40.

Conclusion: Good agreement was found between the CO values obtained by the APCO and TD techniques throughout the intraoperative period including the period of coronary artery graft surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jvca.2008.02.015DOI Listing

Publication Analysis

Top Keywords

patients undergoing
12
coronary artery
12
cardiac output
8
arterial pressure
8
pressure waveform
8
waveform analysis
8
bolus thermodilution
8
thermodilution technique
8
off-pump coronary
8
artery bypass
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!