Background: Metallic allergy is associated with restenosis following bare metal stent implantation, but the impact of metallic allergy on the outcome after implantation of drug-eluting stents (DES) has not been investigated.

Methods And Results: The present study group consisted of 88 consecutive patients (109 lesions) who underwent percutaneous coronary intervention with sirolimus-eluting stents (SES). Follow-up angiography was obtained at 8 months in all patients. At that time, the patients underwent epicutaneous patch tests for nickel, chromate, molybdenum, manganese, and titanium, which were evaluated after 48 h of contact. The patch test was positive in 14 patients (16%) (5 for manganese, 3 for nickel, 1 for chromate, 1 for Nickel and manganese, and 4 for manganese and chromate). The binary restenosis rate in the patients with a positive patch test was similar to those with negative patch test (6.3% vs 6.5%, p=0.98). Serial quantitative coronary angiography analyses identified no significant differences in late lumen loss of in-stent segments between patients with positive patch test and those with negative patch test (0.19+/-0.49 mm vs 0.12+/-0.48 mm, p=0.55).

Conclusion: SES prevent restenosis irrespective of metallic allergy. The classic relationship between metallic allergy and in-stent restenosis, seen with bare metal stents, does not appear to arise with DES, possibly because of the immunosuppressive effect of sirolimus.

Download full-text PDF

Source
http://dx.doi.org/10.1253/circj.72.893DOI Listing

Publication Analysis

Top Keywords

metallic allergy
20
patch test
20
sirolimus-eluting stents
8
irrespective metallic
8
restenosis bare
8
bare metal
8
nickel chromate
8
patients positive
8
positive patch
8
test negative
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!