A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A spectrofluorimetric sequential injection method for the determination of penicillamine using fluorescamine in the presence of beta-cyclodextrins. | LitMetric

A simple, robust and sensitive sequential injection spectrofluorimetric method for the determination of penicillamine (PA) in pharmaceutical formulations is developed. The method is based on the formation of a highly fluorescent derivative when penicillamine is reacted with fluorescamine (FL) in borate buffer of pH 9.3. The derivative produced is monitored at an emission wavelength of 495 nm using an excitation wavelength of 355 nm. The optimum conditions for the determination of PA with FL were: 3 mM FL, pH 9.3, 5 mM methyl-beta-cyclodextrin, sample volume of 75 microL and reagent volume of 75 microL. Furthermore, the effect of various media on the fluorescence intensity of the PA-FL derivative was studied and methyl-beta-cyclodextrin was found to give the largest enhancement. A linear dynamic range for the determination of PA of 5-80 ppm was obtained with a sampling frequency of 50 h(-1) and a relative standard deviation of less than 2.5%. The method was applied to the determination of PA in pharmaceutical formulations with reasonable recoveries ranging from 101.0-103.1%, indicating that no interference is observed from concomitants usually present in dosage forms.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10895-008-0363-9DOI Listing

Publication Analysis

Top Keywords

sequential injection
8
method determination
8
determination penicillamine
8
pharmaceutical formulations
8
volume microl
8
determination
5
spectrofluorimetric sequential
4
method
4
injection method
4
penicillamine fluorescamine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!