Radiation doses of radiologists, assistants and patients during 21 percutaneous nephrostomies (PN) (including 11 unilateral and 5 bilateral procedures) were measured using an area-exposure meter and thermoluminescent dosimeters. The mean fluoroscopy time per PN was 12 min and the mean product of air kerma and the cross-sectional area of the fluoroscopic beam was 8.0 (range 0.41-24) Gycm2. Doses to the radiologists and assistants were generally modest, and the yearly dose limits of ICRP will not be exceeded in practice. The doses to the radiologist's fingers were found to be the most restrictive in this study. Regarding the mean dose to the radiologist's fingers (190 muGy), the yearly dose limit of 500 mSv would be exceeded after about 2600 PNs provided that his fingers are not otherwise exposed. With the maximal finger dose of 1100 muGy, this would occur after about 450 yearly PNs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-2008-1033126 | DOI Listing |
J Clin Rheumatol
January 2025
From the Department of Rheumatology, Brooke Army Medical Center, Fort Sam Houston, TX.
Background: In this case series, we present longitudinal imaging surveillance of 6 cases of osseous sarcoidosis, each of which was effectively treated with tumor necrosis factor (TNF) inhibition.
Methods: We identified 6 patients from Brooke Army Medical Center with osseous sarcoidosis, who were treated with TNF inhibition and followed with longitudinal imaging studies. Cases of osseous sarcoidosis were defined as having pathologic evidence of noncaseating granulomas on bone biopsy and evidence of osseous lesions on imaging attributable to sarcoidosis by the radiologist, treating clinician, and reviewer.
Acad Radiol
January 2025
Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (R.D., J.M.B., B.S., J.M., S.G., P.K., S.W., J.H., K.N., S.A., A.B.).
Rationale And Objectives: Photon Counting CT (PCCT) offers advanced imaging capabilities with potential for substantial radiation dose reduction; however, achieving this without compromising image quality remains a challenge due to increased noise at lower doses. This study aims to evaluate the effectiveness of a deep learning (DL)-based denoising algorithm in maintaining diagnostic image quality in whole-body PCCT imaging at reduced radiation levels, using real intraindividual cadaveric scans.
Materials And Methods: Twenty-four cadaveric human bodies underwent whole-body CT scans on a PCCT scanner (NAEOTOM Alpha, Siemens Healthineers) at four different dose levels (100%, 50%, 25%, and 10% mAs).
Indian J Nucl Med
November 2024
Department of Nuclear Medicine and Molecular Imaging, Advanced Centre for Treatment Research and Education in Cancer, Tata Memorial Centre, Mumbai, Maharashtra, India.
Objective: Lu-DOTATATE peptide receptor therapy (PRRT) is an established treatment for patients suffering from neuroendocrine tumors. In the last few years, intra-arterial PRRT is being considered for patients having liver metastatic disease predominantly. The aim of our study is to measure the radiation doses received by the treating intervention radiologists involved in intra-arterial PRRT treatment using Lu-DOTATATE.
View Article and Find Full Text PDFPol J Radiol
November 2024
University Center of Excellence in Urology, Wroclaw Medical University, Wroclaw, Poland.
Purpose: The incidence of renal cell carcinoma has been steadily increasing over the past two decades, raising the need for minimally invasive approaches. We sought to present the methodology of the percutaneous cryoablation (PCA) procedure developed based on one year of experience with 81 PCA procedures.
Material And Methods: The percutaneous cryoablation programme at Wroclaw Medical University Hospital has been successfully operating for a year.
J Imaging Inform Med
January 2025
Monash Imaging, Monash Health, 246 Clayton Rd, Clayton, VIC, 3168, Australia.
We extend existing techniques by using generative adversarial network (GAN) models to reduce the appearance of cast shadows in radiographs across various age groups. We retrospectively collected 11,500 adult and paediatric wrist radiographs, evenly divided between those with and without casts. The test subset consisted of 750 radiographs with cast and 750 without cast.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!