Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The effects of airborne particulate matter (PM) are a major human health concern. In this panel study, we evaluated the acute effects of exposure to PM on peak expiratory flow (PEF) and wheezing in children.
Methods: Daily PEF and wheezing were examined in 19 asthmatic children who were hospitalized in a suburban city in Japan for approximately 5 months. The concentrations of PM less than 2.5 mum in diameter (PM(2.5)) were monitored at a monitoring station proximal to the hospital. Moreover, PM(2.5) concentrations inside and outside the hospital were measured using the dust monitor with a laser diode (PM(2.5(LD))). The changes in PEF and wheezing associated with PM concentration were analyzed.
Results: The changes in PEF in the morning and evening were significantly associated with increases in the average concentration of indoor PM(2.5(LD)) 24 h prior to measurement (-2.86 L/min [95%CI: -4.12, -1.61] and -3.59 L/min [95%CI: -4.99, -2.20] respectively, for 10-mug/m(3) increases). The change in PEF was also significantly associated with outdoor PM(2.5(LD)) concentrations, but the changes were smaller than those observed for indoor PM(2.5(LD)). Changes in PEF and concentration of stationary-site PM(2.5) were not associated. The prevalence of wheezing in the morning and evening were also significantly associated with indoor PM(2.5(LD)) concentrations (odds ratios = 1.014 [95%CI: 1.006, 1.023] and 1.025 [95%CI: 1.013, 1.038] respectively, for 10-microg/m(3) increases). Wheezing in the evening was significantly associated with outdoor PM(2.5(LD)) concentration. The effects of indoor and outdoor PM(2.5(LD)) remained significant even after adjusting for ambient nitrogen dioxide concentrations.
Conclusion: Indoor and outdoor PM(2.5(LD)) concentrations were associated with PEF and wheezing among asthmatic children. Indoor PM(2.5(LD)) had a more marked effect than outdoor PM(2.5(LD)) or stationary-site PM(2.5).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4771604 | PMC |
http://dx.doi.org/10.2188/jea.je2007432 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!