Percentage depth dose (PDD) curves were obtained for 50 kV and 100 kV x-rays on a Gulmay Medical D3000 DXR unit. Different dosimetry systems were compared including a Scanditronix Wellhofer small volume cylindrical ion chamber, a Wellhofer photon PFD diode, a PTW soft x-ray parallel plate chamber (N23342) and two types of radiochromic film: GafChromic EBT and GafChromic MD55. The PDD curves were also compared to BEAMnrc Monte Carlo predictions. GafChromic film was found to be a valid choice of dosimeter for measuring percentage depth dose curves at 100 kV and 50 kV. All the dosimeters showed agreement with predictions at depths greater than 10 mm, while near the surface GafChromic film and PFD diodes give the best agreement to Monte Carlo values.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0031-9155/53/11/N02 | DOI Listing |
Phys Med
January 2025
IRCCS San Raffaele Scientific Institute, Experimental Imaging Center, Milan, Italy. Electronic address:
Purpose: Minibeam radiotherapy (MBRT) uses small parallel beams of radiation to create a highly modulated dose pattern. The aim of this study is to develop an optical radioluminescence imaging (RLI) approach to perform real-time dose measurement for MBRT.
Methods: MBRT was delivered using an image-guided small animal irradiator equipped with a custom collimator.
Health Phys
January 2025
Department of Physics, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario, M5B 2K3.
This study elucidated the radiation response characteristics of a Gafchromic radiochromic film subjected to low photon doses of ≤50 mSv, which corresponds to the annual whole body effective dose limit for radiation workers in Canada. Radiochromic films are investigated for possible use as a complementary tool for the Canadian Armed Forces that can be worn in addition to their existing personal dosimetry to quickly assess personal radiation dose received from radiological hazards without reliance on electronics. The films were exposed to varying photon energies emanating from x-ray generators and radioisotopes, specifically cesium-137, cobalt-60, and americium-241.
View Article and Find Full Text PDFMed Phys
December 2024
Department of Physics, The Verspeeten Family Cancer Centre, London, Ontario, Canada.
Background: Stereotactic arrythmia radioablation (STAR) is a noninvasive technique to treat ventricular tachycardia (VT). Management of cardiorespiratory motion plays an essential role in VT-STAR treatments to improve treatment outcomes by reducing positional uncertainties and increasing dose conformality. Use of an electrocardiogram (ECG) signal, acquired in real-time, as a surrogate to gate the beam has the potential to fulfil that intent.
View Article and Find Full Text PDFBiomed Phys Eng Express
December 2024
Medical Physics Consultant, INTECNUS Foundation, RP82 8400, San Carlos de Bariloche, Río Negro, Argentina.
. To investigate the effect of the position and orientation of the detector and its influence on the determination of output factors (OF) for small fields for a linear accelerator (MR-linac) integrated with 1.5 T magnetic resonance following the TRS-483 formalism.
View Article and Find Full Text PDFJ Contemp Brachytherapy
August 2024
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.