A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Resolution acuity for equiluminant gratings of S-cone positive or negative contrast in human vision. | LitMetric

Resolution acuity for equiluminant gratings of S-cone positive or negative contrast in human vision.

J Vis

Visual Science Research Group, School of Biomedical Sciences, University of Ulster, Coleraine, Northern Ireland, UK.

Published: March 2008

We measured resolution acuity separately for gratings with positive (+S) and negative (-S) S-cone contrast at different eccentricities in the temporal retina to determine if the resolution performance is limited by a single bipolar opponent mechanism. Gratings were modulated from an achromatic background in either the 90 or 270 deg direction in DKL space. Two additional directions were tested to examine the effects of increased lens yellowing and macular pigment absence in the periphery. The gratings used slow temporally rising hue (co-sinusoidal step) to aid selective S-cone ON or OFF stimulation. Resolution acuity was measured using different luminance ratios of the grating bars with the background around the equiluminant point. The data displayed a plateau where the acuity was minimal and mediated by the sparse S-cone pathway, with observer performance rising on either side. The acuity at the minimum was consistently higher for +S gratings than -S gratings beyond 10 deg eccentricity. Above the resolution limit, an aliased pattern was detected for both types of gratings, indicating that the resolution acuity was limited by the density of postreceptoral neurons. The results suggest that the resolution of gratings with opposite S-cone contrast polarity is limited by separate and rectified mechanisms of different distribution.

Download full-text PDF

Source
http://dx.doi.org/10.1167/8.3.9DOI Listing

Publication Analysis

Top Keywords

resolution acuity
16
gratings
8
positive negative
8
s-cone contrast
8
resolution
7
s-cone
5
acuity
5
acuity equiluminant
4
equiluminant gratings
4
gratings s-cone
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!