Unlabelled: Iodine kinetics and lesion dose per administered 131I activity (LDpA) of differentiated thyroid cancer metastases were determined using 124I PET. These data were analyzed to derive an optimized dosimetry protocol.

Methods: We evaluated the time-activity-concentration curves of 37 lesions in 17 patients who had undergone thyroidectomies. LDpA determination involved 124I PET images acquired at 4, 24, 48, 72, and 96 h after intake of a capsule containing 20-40 MBq of 124I. A combination of a linear and a monoexponential or a monoexponential function only parameterized the time-activity-concentration curves. The LDpAs, calculated using data from all 5 PET time points, served as reference. The lesions were classified into 3 groups, according to potential for cure with 131I therapy: low (< or =5 Gy GBq(-1); n = 14), medium (between 5 and 10 Gy GBq(-1); n = 9), or high LDpAs (>10 Gy GBq(-1); n = 14). Using the reference approach, the differences in the empiric kinetic parameters within the LDpA groups were evaluated. The reference LDpAs were compared with those derived from only 2, 3, or 4 PET data points and from 1 adapted 2-point approach. Lin's concordance correlation coefficient (rho c) and the mean absolute percentage deviation in LDpAs were used to assess agreement between simplified and reference approaches.

Results: The effective 124I half-life, linear activity-concentration rate (alpha), and 24-h activity concentration (CpA) (the latter 2 per administered 124I activity) differed significantly among the LDpA groups (P < 0.05). LDpAs correlated with 24-h CpAs (r = 0.94, P < 0.001). Using the 4-, 24-, and 96-h measurements, a rho c value of greater than or equal to 0.90 was found, and the mean absolute percentage deviation was less than or equal to 16%. Similar statistical values were obtained for the adapted approach, which was based on 24- and 96-h PET data points only.

Conclusion: Lesion classification into LDpA groups was feasible using a single PET scan at approximately 24 h. Because of the highly variable kinetics, 1 additional measurement at approximately 96 h was needed to obtain a sufficiently reliable LDpA estimate. The adapted 24-96-h approach appears to be the optimal 124I protocol and is a reliable simplification of the 5-point protocol.

Download full-text PDF

Source
http://dx.doi.org/10.2967/jnumed.107.047159DOI Listing

Publication Analysis

Top Keywords

124i pet
12
pet data
12
ldpa groups
12
differentiated thyroid
8
thyroid cancer
8
time-activity-concentration curves
8
data points
8
absolute percentage
8
percentage deviation
8
24- 96-h
8

Similar Publications

Kirsten rat sarcoma (KRAS) is a frequently mutated oncogene responsible for several oncogenic KRAS variants and for driving tumor proliferation. Some nonsmall cell lung cancer (NSCLC) tumors exhibit KRAS G12C mutations, which can be targeted for inhibition using covalent and more recently noncovalent inhibitors. Sotorasib was the first FDA-approved G12C inhibitor that has shown efficacy in lung cancer patients, but with mixed responses.

View Article and Find Full Text PDF
Article Synopsis
  • Tumor-Associated Macrophages (TAMs) are crucial in the development and progression of ovarian cancer, and a PET radiotracer called [I]iodo-DPA-713 is being used to image these macrophages in various tumor contexts.
  • The study utilized PET/MRI imaging to visualize TAM activity in primary and metastatic tumors in a mouse model, showing significant radiotracer uptake in the vicinity of the tumors and in areas affected by ascites.
  • Results indicated a strong correlation between PET tracer uptake and the presence of TAMs surrounding tumors, with distinct uptake patterns observed in both primary and secondary tumor sites, as well as in the gastrointestinal tract of affected mice.
View Article and Find Full Text PDF
Article Synopsis
  • 124-iodine (I) is essential for PET diagnostics and therapy in differentiated thyroid cancer (DTC), but detecting small lesions (<10 mm) poses significant challenges due to low iodine uptake.
  • The study aimed to evaluate the effectiveness of non-time-of-flight (TOF) PET/MRI in identifying and quantifying small DTC lymph node lesions under difficult imaging conditions.
  • Results indicated that longer acquisition times, higher activity concentrations, and advanced reconstruction algorithms improved lesion visibility, with the smallest detectable size of 3.7 mm only visible under optimal settings.
View Article and Find Full Text PDF

[F]TFB PET/CT misses intense [I]iodine-avid metastases after redifferentiation therapy in metastatic thyroid cancer.

EJNMMI Res

October 2024

Molecular Imaging and Therapy Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Ave, P.O. Box 77, New York, NY, 10065, USA.

Article Synopsis
  • The study investigates the effectiveness of Fluorine 18-labelled tetrafluoroborate ([F]TFB) as an imaging alternative to iodine for assessing metastatic thyroid cancer and potential radioiodine treatment success.
  • Five patients participated in the research, receiving both [F]TFB and iodine imaging on the same day. Results showed that [F]TFB identified 58% of lesions compared to 91% for iodine imaging, indicating its lower sensitivity.
  • The conclusion drawn highlights that [F]TFB did not successfully predict iodine uptake in patients undergoing redifferentiation therapy, raising questions about its reliability for other treatment cases or in untreated patients.
View Article and Find Full Text PDF

Background: Positron emission tomography (PET) traditionally uses coincident annihilation photons emitted from a positron interacting with an electron to localize cancer within the body. The formation of positronium (Ps), a bonded electron-positron pair, has not been utilized in clinical applications of PET due to the need to detect either the emission of a prompt gamma ray or the decay of higher-order coincident events. Assessment of the lifetime of the formed Ps, however, can potentially yield additional diagnostic information of the surrounding tissue because Ps properties vary due to void size and molecular composition.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!