Three-dimensional assessment of dental casts' occlusal surfaces using two impression materials.

J Oral Rehabil

Department of Orthodontics, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece.

Published: November 2008

The aim of this study was to assess by means of a three-dimensional computed tomography scanning system the occlusal surface characteristics of dental casts made using two different impression materials. Alginate and polyvinyl siloxane impressions were taken of 20 dental students resulting in 40 dental casts. The casts were paired for each student separately so that each pair consisted of an alginate poured cast and a polyvinyl siloxane poured out cast. The casts were scanned using FlashCT scanner and for each cast, a three-dimensional digital image was obtained. The digitized casts were processed using the three-dimensional imaging software Geomagic Studio 9. A total of 464 paired teeth were digitally separated and superimposed. For each tooth, two measurements were obtained corresponding to the two different impression materials used. The two sets of volumes for all digitally separated teeth were compared and analysed using the Wilcoxon signed test. Larger volume measurements were obtained for teeth separated from alginate poured out casts than from their corresponding ones from polyvinyl siloxane casts (P = 0.005). When the teeth were divided into the groups of incisors, canines and premolars/molars, only the last one exhibited significant difference (P = 0.00). The mean difference between the volumes measured for all 464 teeth separated was 0.041 mm(3) (+/-0.33). The occlusal surfaces of teeth appear differently in dental casts depending on the impression materials used. Impressions of dental casts should be utilized with caution in relation to their research application and in reference with dental wear studies.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2842.2008.01872.xDOI Listing

Publication Analysis

Top Keywords

impression materials
16
dental casts
16
polyvinyl siloxane
12
casts
9
occlusal surfaces
8
impressions dental
8
alginate poured
8
poured cast
8
digitally separated
8
teeth separated
8

Similar Publications

Aim: The aim of the present study was to comparatively evaluate the retention of complete dentures and oral health-related quality of life (OHRQoL) of patients with conventional and bioelectric impressions or transcutaneous electric nerve stimulation (TENS).

Materials And Methods: A total of thirty (n = 30) completely edentulous patients were randomly distributed into two groups: Group-C (n = 15) (Conventional) and Group-T (n = 15) (bioelectric). In Group C, border molding was performed using the manual manipulation of borders, and the final impression was made using zinc-oxide eugenol.

View Article and Find Full Text PDF

Background/purpose: Spacing between teeth is a common trait across different stages of dentition. With the tide of the digital impression, the scanning trueness of the intraoral scanner (IOS) is a hot subject. This study aimed to determine the correlation between the level of the spaced dentition and trueness of the intraoral scanning.

View Article and Find Full Text PDF

Background/purpose: The accuracy of intraoral scanners (IOSs) plays a crucial role in the success of final restorations in digital workflows. Previous studies have shown that numerous factors affect the accuracy of IOSs. Most studies have evaluated the accuracy of IOS under one restoration condition.

View Article and Find Full Text PDF

BACKGROUND A tooth preparation's clinical requirements and geometric configurations should take precedence over material characteristics when advocating for putty reline impression techniques for permanent restorations, since they require a technically sensitive spacer for light body elastomer. We evaluated the linear dimensional accuracy of vinyl polysiloxane-based putty reline impressions with different spacer acquisition techniques in short-span and long-span fixed partial dentures (FPD). MATERIAL AND METHODS A typodont tooth set simulated a 3-unit (short-span) and a 5-unit (long-span) FPD.

View Article and Find Full Text PDF

Wooden Plate Denture Reproduced Using Materials and Methods From 400 Years Ago.

Cureus

December 2024

Department of Oral and Maxillofacial Surgery, National Hospital Organization, Kyoto Medical Center, Kyoto, JPN.

This study aimed to reproduce a complete wooden plate denture, which was the first in the world to retain suction under negative pressure, using the same materials and methods from 400 years ago (i.e., the Edo period) to verify its masticatory performance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!