Dynamic distribution of artificial tears on the ocular surface.

Arch Ophthalmol

Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, 1638 NW 10th Ave, McKnight Bldg, Room 506, Miami, FL 33136, USA.

Published: May 2008

Objective: To study the effects of artificial tear viscosity on tear film thickness, upper and lower tear menisci, and tear volume using optical coherence tomography.

Methods: The central tear film and tear menisci before and immediately after the instillation of different artificial tears were imaged in 40 eyes of 20 healthy individuals. Carboxymethylcellulose sodium, 1.0% (viscosity, 70 cP), propylene glycol, 0.3%, and polyethylene glycol, 0.4% (10 cP), carboxymethylcellulose, 0.5% (3 cP), and isotonic sodium chloride solution (1 cP) were tested on 2 consecutive days. All measurements, including tear film thickness, the height, radius, and area of the tear meniscus, and the estimated tear volume, were obtained at 0, 5, 20, 40, and 60 minutes after instillation.

Results: At instillation, all artificial tears and isotonic sodium chloride solution caused an increase in all tear variables (P < .001). Tear film thickness remained significantly elevated for all drops at 5 minutes (P < .001) and returned to baseline at 20 minutes. Other variables returned to baseline at 5 minutes. Comparing the different drops, tear film thickness and lower meniscus variables at instillation were increased with the more viscous drops (P < .05).

Conclusion: Optical coherence tomography demonstrated that all tear preparations, including isotonic sodium chloride solution, increased tear film thickness for at least 5 minutes and other variables immediately after instillation.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archopht.126.5.619DOI Listing

Publication Analysis

Top Keywords

tear film
24
film thickness
20
tear
14
artificial tears
12
isotonic sodium
12
sodium chloride
12
chloride solution
12
tear menisci
8
tear volume
8
optical coherence
8

Similar Publications

Purpose: To evaluate the efficacy and safety of intense pulsed light (IPL) combined with meibomian gland expression (MGX) for the treatment of dry eye disease and meibomian gland dysfunction associated with chronic Stevens-Johnson syndrome and toxic epidermal necrolysis.

Methods: This prospective noncomparative interventional study included 29 patients (58 eyes) who underwent 3 sessions of IPL and MGX at 2-week intervals. Subjective symptoms (ocular surface disease index score) and objective dry eye tests: matrix metalloproteinase 9, tear meniscus height, bulbar redness score, tear film lipid layer thickness (LLT), Schirmer I test, conjunctival and corneal staining, meibomian gland loss, MGX score [meibomian gland score (MGS)], and tear break-up time were assessed at the baseline and after 4, 8, and 12 weeks.

View Article and Find Full Text PDF

Purpose: To compare the meibographies and dry eye parameters of paretic vs non-paretic sides of patients with a facial palsy diagnosis.

Patients And Methods: Twenty patients with unilateral facial palsy were recruited and the severity of the disease was staged using the House-Brackmann scale. A comprehensive dry eye evaluation was performed using the Oculus 5M Keratograph.

View Article and Find Full Text PDF

Blink completeness and rate in dry eye disease: An investigator-masked, prospective registry-based, cross-sectional, prognostic study.

Cont Lens Anterior Eye

January 2025

Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand. Electronic address:

Purpose: To investigate the prognostic ability of blink rate and the proportion of incomplete blinking to predict dry eye disease diagnosis, as defined by the TFOS DEWS II criteria.

Methods: A total of 453 community residents (282 females, 171 males; mean ± SD age, 37 ± 19 years) were recruited in an investigator-masked, prospective registry-based, cross-sectional, prognostic study. Dry eye symptomology, tear film quality, and ocular surface characteristics were assessed in a single clinical session, and blink parameters evaluated by an independent masked observer.

View Article and Find Full Text PDF

Investigation of corneal topographic and ocular surface parameters in ocular rosacea based on skin subtypes.

J Fr Ophtalmol

January 2025

Department of Ophthalmology, Cochin Hospital, Université Paris-Cité, Assistance Publique-Hôpitaux de Paris, Paris, France; Inserm, Centre de Recherche des Cordeliers, Unit 1138 team 17, Paris, France.

Objective: To compare the corneal topographic parameters and ocular surface parameters of ocular rosacea (OR) patients across skin subtypes of the disease and healthy controls.

Methods: This prospective study included 180 eyes of 90 OR patients and 60 eyes of 30 healthy controls. Among the OR patients, 30 had phymatous (60 eyes), 30 had erythematotelangiectatic (60 eyes) and 30 had papulopustular skin types (60 eyes).

View Article and Find Full Text PDF

: Diabetes is a well-recognised factor inducing a plethora of corneal alterations ranging from dry eye to reduced corneal sensibility, epithelial defects, and reduced cicatrisation. This cohort study aimed to assess the efficacy of a novel ophthalmic solution combining cross-linked hyaluronic acid (CHA), chondroitin sulfate (CS), and inositol (INS) in managing diabetes-induced corneal alterations. Specifically, it evaluated the solution's impact on the tear breakup time (TBUT), the ocular surface disease index (OSDI), and corneal sensitivity after three months of treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!