Objective: Our purpose was to examine the use of fully supported open stent grafting (OSG) with a Matsui-Kitamura (MK) stent for treatment of distal arch aneurysm (DAA).
Methods: Surgery was performed using a newly developed device in seven DAA patients (six men and one woman) from 58 to 86 years of age (mean, 73 years old) from August 2005 to June 2007. The aorta was transected at the arch between bracheocephalic artery and left subclavian artery under circulatory arrest with total cardiopulmonary bypass and selective cerebral perfusion; then the stent grafting (SG) system was inserted and positioned with a 14 Fr. pusher. The SG and a transected edge were then sutured and anastomosed with the arch graft. The surgery was completed by constructing three cerebral branches.
Results: The mean SG diameter and length were 34.6 mm (range, 32-38 mm) and 150 mm (120-200 mm), respectively. The mean time of circulatory arrest time and surgery were 41 min (35-55 min) and 358 min (269-450 min), respectively. Simultaneous mitral valve replacement was performed in one patient. All surgeries were completed successfully, and complete thrombosis of the aneurysm was obtained. Paraparesis and respiratory failure occurred in one patient each, and one patient died of brainstem infarction 1 month after surgery.
Conclusion: These initial results suggest that the OSG method is a useful surgical procedure for the treatment of DAA.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11748-007-0223-6 | DOI Listing |
Indian J Thorac Cardiovasc Surg
February 2025
Department of CTVS, AIIMS, Jodhpur, 342005 India.
Carotid artery stenting (CAS) has become a favoured alternative to surgical carotid endarterectomy (CEA) in select cases of critical internal carotid artery (ICA) occlusion. However, complications such as stent migration or entrapment can occur, necessitating prompt diagnosis and intervention. We present a case of a 75-year-old diabetic male who underwent CAS for recurrent presyncope at a private hospital, and during the procedure of CAS the stent was migrated and its proximal part was impacted in the critically narrowed part of the ICA.
View Article and Find Full Text PDFJACC Case Rep
January 2025
Division of Cardiac Surgery, Department of Surgery, Johns Hopkins Hospital, Baltimore, Maryland, USA.
Fibrosing mediastinitis is a rare chronic inflammatory condition characterized by excessive fibrotic process in the mediastinum. Although various infectious processes are more common causes, it can also be related to several malignancies. We report a case of a 28-year-old woman with fibrosing mediastinitis related to an aggressive primary gray-zone lymphoma causing complete occlusion of the superior vena cava (SVC) and the innominate veins.
View Article and Find Full Text PDFCase Rep Cardiol
January 2025
Department of Cardiology, Toyohashi Heart Center, Toyohashi, Aichi, Japan.
We present a case of a 60-year-old man with claudication in his right foot; the patient had received stent-graft implantation for the right superficial femoral artery (SFA) 1 year ago. Computed tomography angiography suggested stent occlusion of the right SFA, and a thrombus was considered to cause occlusion. To avoid distal embolization, we performed lesion recanalization via a trans-ankle intervention.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Institute for Research in Operative Medicine (IFOM), Witten/Herdecke University, Cologne, Germany.
Purpose: Our aim was to update evidence-based and consensus-based recommendations for the inhospital endovascular management of haemorrhage and vascular lesions in patients with multiple and/or severe injuries based on current evidence. This guideline topic is part of the 2022 update of the German Guideline on the Treatment of Patients with Multiple and/or Severe Injuries.
Methods: MEDLINE and Embase were systematically searched to June 2021.
J Craniofac Surg
November 2024
Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
Background: The septum is often underdeveloped in East Asian populations, and traditional endogenous extension stents may not adequately fulfill the requirements for rhinoplasty. Herein, we present an innovative exogenous extension framework featuring a mortise and tenon structure specifically designed for East Asians.
Methods: This framework comprises a mushroom-shaped rib cartilage component and a lancet-shaped expanded polytetrafluoroethylene (ePTFE) element, which are interconnected through a mortise and tenon design.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!