Alteration of proximal conduction velocity at distal nerve injury in carpal tunnel syndrome: demyelinating versus axonal change.

J Clin Neurophysiol

Section of Neurology, Taichung Veterans General Hospital, Taichung, and Department of Neurology, Chung-Shan Medical University, Taichung, Taiwan.

Published: June 2008

The objective of this study was to determine the cause of median forearm motor conduction velocity (FMCV) slowing in patients with carpal tunnel syndrome, due to either focal conduction abnormality over wrist or retrograde conduction slowing, and to decide whether the slowing is related to severity of compression or not. Fifty carpal tunnel syndrome patients confirmed by conventional nerve conduction study with abnormal electromyography of the abductor pollicis brevis muscle were group 1, and 100 with normal electromyography, group 2. One hundred volunteers served as controls. In addition to conventional nerve conduction study of median and ulnar nerves, palmar stimulations for median mixed and motor nerves were also performed to calculate wrist-palm mixed nerve conduction time and motor conduction velocity (W-P MCV). For group 1, group 2, and control subjects, respectively, W-P MCV were 19.73+/-7.65 (mean+/-SD), 32.7+/-6.83, and 52.75+/-6.4 m/s, whereas median FMCV were 48.63+/-8.32, 54.42+/-2.11, and 57.86+/-4.24 m/s. There was a significant reduction in the W-P MCV (62.6%, P<0.00001) and a decrease in the median FMCV (15.95%, P<0.00001) in group 1, and 38% reduction in W-P MCV (P<0.00001) and 5.9% decrease in median FMCV (P<0.00001) in group 2 when compared with controls, but ulnar FMCV and sensory nerve conduction study results did not, suggesting the reduction of median W-P MCV is not parallel with that of median FMCV in both patients groups. Furthermore, there is a poor correlation of median FMCV and W-P MCV in patient groups, implying conduction blockage of the large myelinating fibers at the wrist, leaving only slower axons to be measured, is not the likely cause of reduction of FMCV. In addition, the reduction of compound muscle action potential amplitude of abductor pollicis brevis muscle, conduction block at wrist and weak correlation of median FMCV and compound muscle action potential amplitude of abductor pollicis brevis exclusively occurred in group 1. Therefore, the retrograde conduction slowing really occurs among patients with carpal tunnel syndrome-markedly in those with abnormal electromyography and mildly in those with only demyelination. This finding counters conventional wisdom that nerve function changes only in segments distal to injured sites.

Download full-text PDF

Source
http://dx.doi.org/10.1097/WNP.0b013e3181775981DOI Listing

Publication Analysis

Top Keywords

conduction velocity
12
carpal tunnel
12
tunnel syndrome
12
nerve conduction
12
w-p mcv
12
conduction
8
motor conduction
8
conventional nerve
8
conduction study
8
alteration proximal
4

Similar Publications

Echocardiography is crucial for evaluating patients at risk of clinical deterioration. Left ventricular ejection fraction (LVEF) and velocity time integral (VTI) aid in diagnosing shock, but bedside calculations can be time-consuming and prone to variability. Artificial intelligence technology shows promise in providing assistance to clinicians performing point-of-care echocardiography.

View Article and Find Full Text PDF

Background/objectives: The active straight leg raise requires intricate coordination between the hip, knee, pelvis, and spine. Despite its complexity, limited research has explored the relationship between lower limb raising velocity and trunk muscle motor control during an active straight leg raise in healthy individuals. This study aimed to explore the potential effects of increased lower limb raising velocity on core muscle contractions during active straight leg raises.

View Article and Find Full Text PDF

Although the Doppler velocity log is widely applied to measure underwater fluid flow, it requires high power and is inappropriate for measuring low flow velocity. This study proposes a fluid flow sensor that utilizes optical flow sensing. The proposed sensor mimics the neuromast of a fish by attaching a phosphor to two pillar structures (A and B) produced using ethylene propylene diene monomer rubber.

View Article and Find Full Text PDF

Preparation and Performance Evaluation of CO Foam Gel Fracturing Fluid.

Gels

December 2024

Key Laboratory of Unconventional Oil & Gas Development, China University of Petroleum (East China), Ministry of Education, Qingdao 266580, China.

The utilization of CO foam gel fracturing fluid offers several significant advantages, including minimal reservoir damage, reduced water consumption during application, enhanced cleaning efficiency, and additional beneficial properties. However, several current CO foam gel fracturing fluid systems face challenges, such as complex preparation processes and insufficient viscosity, which limit their proppant transport capacity. To address these issues, this work develops a novel CO foam gel fracturing fluid system characterized by simple preparation and robust foam stability.

View Article and Find Full Text PDF

Inspired by the ultrafast directional water transport structure of Sarracenia trichomes, hierarchical textured surfaces with specific microgrooves were prepared based on laser processing combined with dip modification, in response to the growing problem of freshwater scarcity. The prepared surfaces were tested for droplet transport behavior to investigate the relationship between the surface structure and the driving force of directional water transport and their effects on the water transport distance and water transport velocity. The results showed that surfaces with a superhydrophobic background associated channels of multirib structures, and a dual-gradient surface of gradient hydrophobic background associated channels with gradient structure performed the best in terms of water transport efficiency.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!