A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of critical renal ischemia with real-time infrared imaging. | LitMetric

Assessment of critical renal ischemia with real-time infrared imaging.

J Surg Res

Laboratory of Bioengineering and Physical Science, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, Maryland, USA.

Published: October 2008

Background: Currently visual and tactile clues such as color, mottling, and tissue turgor are used in the operating room for subjective assessments of organ ischemia. Studies have demonstrated that infrared (IR) imaging is a reliable tool to identify perfusion of brain tumors and kidneys during human surgery. Intraoperative IR imaging has the potential for more objective real-time detection and quantitative assessment of organ viability including early ischemia. We hypothesize, by detecting variations of the IR signal, we can assess the degree to which renal surface temperature reflects underlying renal ischemia. To address this hypothesis, IR imaging-derived temperature fluctuations were evaluated during laparotomy in a porcine model (n = 15). These temperature profiles then underwent spectral (frequency) analysis to assess their relationship to well-described oscillations of the microcirculation.

Materials And Methods: An IR camera was positioned 30-60 cm above the exposed kidneys. Images (3-5 mum wavelength) were collected (1.0/s) at baseline, during warm renal ischemia, and during reperfusion. Dominant frequency (DF) of the tissue temperature fluctuations were determined by a Fourier transformation (spectral) analysis.

Results: IR images immediately showed which segments of the kidney were ischemic. DF at approximately 0.008 Hz that corresponds to blood flow oscillations was observed in thermal profiles. The oscillations were diminished or disappeared after 25 min of warm ischemia and were recovered with reperfusion in a time-dependent fashion. Oscillations were attenuated substantially in ischemic segments, but not in perfused segments of the kidney.

Conclusions: The described oscillations can be measured noninvasively using IR imaging in the operating room, as represented by the DF, and may be an early marker of critical renal ischemia.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jss.2008.02.007DOI Listing

Publication Analysis

Top Keywords

renal ischemia
16
critical renal
8
infrared imaging
8
operating room
8
temperature fluctuations
8
ischemia
7
renal
5
oscillations
5
assessment critical
4
ischemia real-time
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!