A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of surface topography on removal of cortical bone screws in a novel sheep model. | LitMetric

Effect of surface topography on removal of cortical bone screws in a novel sheep model.

J Orthop Res

School of Biosciences & Cardiff Institute of Tissue Engineering and Repair, Cardiff University, Museum Avenue, Cardiff, CF10 3US, Wales, United Kingdom.

Published: October 2008

Difficulty in removing implants used in trauma patients can be a complication, and increased bone-implant adhesion likely is a major contributing factor. In vitro studies have shown that surface morphology of implant materials has the ability to influence cellular responses, with polished surfaces decreasing the potential for mineralization. This study examined the effect of polishing commercially pure titanium (cpTi) and the titanium alloy TAN on the removal torque and percentage bone-implant contact in cortical and cancellous bone of sheep. Polishing had a significant effect on both removal torque and percentage bone-implant contact, with the polished implants demonstrating a lower removal torque in both cortical and cancellous bone. Polished cpTi and stainless steel were similar in terms of surface roughness and removal torque. However, polished TAN, which was not as smooth as polished cpTi, did not show the same low level for reducing removal torque. Improved polishing of TAN should reduce the removal torque further. The results of the study show that polishing is promising in improving the ease of implant removal after fracture fixation and repair.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jor.20665DOI Listing

Publication Analysis

Top Keywords

removal torque
24
removal
8
torque percentage
8
percentage bone-implant
8
bone-implant contact
8
cortical cancellous
8
cancellous bone
8
polished cpti
8
torque
6
polished
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!