Purpose: The quality of anticoagulation therapy in patients with antiphospholipid syndrome (APS) was evaluated.

Summary: The high risk of unnecessary anticoagulation and recent changes in the recommended International Normalized Ratio (INR) target range prompted a performance-improvement initiative to improve the care of patients with APS within the University of Iowa Hospitals and Clinics internal medicine and family medicine anticoagulation clinics. Twenty-three patients with an initial diagnosis of APS were evaluated through chart review to determine the anticoagulation indication, occurrence of thromboembolic events, and INR target range. Confirmation of APS diagnosis was made using Sapporo criteria. Recommendations were made to the patients' physicians for confirmatory APS testing and changes in the anticoagulation regimen. INR target ranges were 2.0-3.0, 2.5-3.5, and 2.5-3.0 for 57%, 39%, and 4% of patients, respectively. Only 6 (26%) of the 23 patients met Sapporo criteria for a definite diagnosis of APS. Of the 17 patients (74%) who did not meet these criteria, 8 (47%) had another indication for indefinite anticoagulation. Repeat APS testing was indicated for 7 patients, 5 of whom met Sapporo criteria for APS. A lower target INR range of 2.0-3.0 was determined appropriate for 6 (26%) of the 23 patients evaluated.

Conclusion: A majority of patients with an initial diagnosis of APS did not meet criteria for a definite diagnosis of APS. Of those patients, approximately half had another indication for long-term anticoagulation, and one third were receiving warfarin dosages based on an INR target range that was higher than clinically indicated.

Download full-text PDF

Source
http://dx.doi.org/10.2146/ajhp060269DOI Listing

Publication Analysis

Top Keywords

inr target
16
diagnosis aps
16
target range
12
sapporo criteria
12
patients
11
aps
10
patients antiphospholipid
8
antiphospholipid syndrome
8
patients initial
8
initial diagnosis
8

Similar Publications

Warfarin is a commonly employed anticoagulant drug aimed at rapidly reaching the optimal international normalized ratio (INR), potentially reducing the hospitalization time in clinical settings. However, limited research has been conducted on the influencing factors and the safety implications of promptly reaching the target INR range in patients with valvular heart disease who have undergone valve replacement or repair. The present study aimed to assess the factors related to the safety considerations of rapidly reaching the target INR range in patients treated with warfarin.

View Article and Find Full Text PDF

Application of low-intensity anticoagulation after On-X mechanical aortic valve replacement.

J Cardiothorac Surg

January 2025

Cardiac Surgery Center, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Affiliated Hospital of University of Electronic Science and Technology, Chengdu, Sichuan Province, 610072, China.

Objective: To explore the safety and efficacy of low-intensity anticoagulation in patients after On-X mechanical aortic valve replacement.

Methods: A total of 104 patients undergoing aortic valve replacement in Cardiac Surgery Department of Sichuan Provincial People's Hospital from December 2018 to December 2021 were randomly divided into low-intensity anticoagulant (INR:1.5-2.

View Article and Find Full Text PDF

Importance: The Aspirin and Hemocompatibility Events With a Left Ventricular Assist Device in Advanced Heart Failure (ARIES-HM3) study demonstrated that aspirin may be safely eliminated from the antithrombotic regimen after HeartMate 3 (HM3 [Abbott Cardiovascular]) left ventricular assist device (LVAD) implantation. This prespecified analysis explored whether conditions requiring aspirin (prior percutaneous coronary intervention [PCI], coronary artery bypass grafting [CABG], stroke, or peripheral vascular disease [PVD]) would influence outcomes differentially with aspirin avoidance.

Objective: To analyze aspirin avoidance on hemocompatibility-related adverse events (HRAEs) at 1 year after implant in patients with a history of CABG, PCI, stroke, or PVD.

View Article and Find Full Text PDF

Introduction: Epistaxis is a prevalent clinical condition that can be associated with significant morbidity and places a considerable burden on the healthcare system.

Aim: To ascertain the prevalence of epistaxis in our center and to identify the predictive factors of severity.

Methods: This is a retrospective cross-sectional analytical study of patients who presented to and/or were admitted for epistaxis at our department of Ear, Nose and Throat (ENT) during the period from January 2015 to December 2022.

View Article and Find Full Text PDF

Outcomes of percutaneous endoscopic gastrostomy (PEG) in HIV patients.

BMC Gastroenterol

December 2024

Division of Gastroenterology, Department of Medicine, BronxCare Health System, Clinical Affiliate of Mt Sinai Health Systems and Academic Affiliate of Icahn School of Medicine, 10C, 1650 Selwyn Avenue, Bronx, NY, 10457, USA.

Background: Percutaneous Endoscopic Gastrostomy (PEG) tube insertion, a routine procedure for long-term enteral nutrition, serves as a crucial intervention for patients who are incapable of tolerating oral intake or meeting adequate nutritional requirements. PEG tube placement carries complications like bleeding and infection. Impact of PEG tubes on the 30-day and long-term mortality in HIV patients is unknown.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!