Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: The murine local lymph node assay (LLNA) is an accepted and widely used method for assessing the skin-sensitizing potential of chemicals. Here, we describe a non-radio isotopic modified LLNA in which adenosine triphosphate (ATP) content is used as an endpoint instead of radioisotope (RI); the method is termed LLNA modified by Daicel based on ATP content (LLNA-DA).
Methods: Groups of female CBA/JNCrlj mice were treated topically on the dorsum of both ears with test chemicals or a vehicle control on days 1, 2, and 3; an additional fourth application was conducted on day 7. Pretreatment with 1% sodium lauryl sulfate solution was performed 1 h before each application. On day 8, the amount of ATP in the draining auricular lymph nodes was measured as an alternative endpoint by the luciferin-luciferase assay in terms of bioluminescence (relative light units, RLU). A stimulation index (SI) relative to the concurrent vehicle control was derived based on the RLU value, and an SI of 3 was set as the cut-off value.
Results: Using the LLNA-DA method, 31 chemicals were tested and the results were compared with those of other test methods. The accuracy of LLNA-DA vs LLNA, guinea pig tests, and human tests was 93% (28/30), 80% (20/25), and 79% (15/19), respectively. The estimated concentration (EC) 3 value was calculated and compared with that of the original LLNA. It was found that the EC3 values obtained by LLNA-DA were almost equal to those obtained by the original LLNA.
Discussion: The SI value based on ATP content is similar to that of the original LLNA as a result of the modifications in the chemical treatment procedure, which contribute to improving the SI value. It is concluded that LLNA-DA is a promising non-RI alternative method for evaluating the skin-sensitizing potential of chemicals.