Radiotherapy represents the most widely spread technique to control and treat cancer. To increase the treatment efficiency, high energy linacs are used. However, applying high energy photon beams leads to a non-negligible dose of neutrons contaminating therapeutic beams. In addition, using conventional linacs necessitates applying wedge filters in some clinical conditions. However, there is not enough information on the effect of these filters on the photoneutrons produced. The aim of this study was to investigate the change of photoneutron dose equivalent due to the use of linac wedge filters. A high energy (18 MV) linear accelerator (Elekta SL 75/25) was studied. Polycarbonate films were used to measure the dose equivalent of photoneutrons. After electrochemical etching of the films, the neutron dose equivalent was calculated using Hp(10) factor, and its variation on the patient plane at 0, 5, 10, 50 and 100 cm from the center of the X-ray beam was determined. By increasing the distance from the center of the X-ray beam towards the periphery, the photoneutron dose equivalent decreased rapidly for the open and wedged fields. Increasing of the field size increased the photoneutron dose equivalent. The use of wedge filter increased the proportion of the neutron dose equivalent. The increase can be accounted for by the selective absorption of the high energy photons by the wedge filter.

Download full-text PDF

Source
http://dx.doi.org/10.1269/jrr.07066DOI Listing

Publication Analysis

Top Keywords

dose equivalent
24
high energy
20
photoneutron dose
16
wedge filters
12
dose
8
filters high
8
polycarbonate films
8
neutron dose
8
center x-ray
8
x-ray beam
8

Similar Publications

Superior Anti-Tumor Response After Microbeam and Minibeam Radiation Therapy in a Lung Cancer Mouse Model.

Cancers (Basel)

January 2025

Department of Radiation Oncology, TUM School of Medicine and Health and Klinikum rechts der Isar, University Hospital of the Technical University of Munich, Ismaninger Straße 22, 81675 Munich, Germany.

Objectives: The present study aimed to compare the tumor growth delay between conventional radiotherapy (CRT) and the spatially fractionated modalities of microbeam radiation therapy (MRT) and minibeam radiation therapy (MBRT). In addition, we also determined the influence of beam width and the peak-to-valley dose ratio (PVDR) on tumor regrowth.

Methods: A549, a human non-small-cell lung cancer cell line, was implanted subcutaneously into the hind leg of female CD1 mice.

View Article and Find Full Text PDF

Background: The use of in-vivo dosimetry is a long-standing but also labor-intensive component of risk-level assessment for patients with implanted devices. A calculation-only approach, using treatment planning system (TPS)-calculated doses along with imaging doses estimates when relevant, has the potential to streamline the physics workflow without negatively impacting patient safety.

Purpose: To evaluate the feasibility of using a calculation-only approach for risk level assessment for patients with implanted electronic medical devices.

View Article and Find Full Text PDF

Introduction: We aimed to evaluate the efficacy and safety of enfortumab vedotin therapy for a cohort of older Japanese patients with metastatic urothelial carcinoma compared to younger patients.

Materials And Methods: We retrospectively evaluated patients with metastatic urothelial carcinoma treated with enfortumab vedotin and recruited between April 2019 and February 2023. Older patients were defined as being ≥75 years old.

View Article and Find Full Text PDF

Understanding renal pelvis pressure (P) during ureteroscopy (URS) has become increasingly important. High irrigation rates, desirable to maintain visualization and limit thermal dose, can increase P. Use of a multi-channel ureteroscope (m-ureteroscope) with a dedicated drainage channel is one strategy that may facilitate simultaneous low P and high flowrate.

View Article and Find Full Text PDF

Outcomes With Radiation Therapy as Primary Treatment for Unresectable Cutaneous Head and Neck Squamous Cell Carcinoma.

Clin Oncol (R Coll Radiol)

December 2024

Radiation Oncology Network, Westmead Hospital, Westmead, NSW, Australia; Sydney Medical School, The University of Sydney, Camperdown, NSW 2006, Australia. Electronic address:

Aims: Unresectable cutaneous squamous cell cancer of the head and neck (HNcSCC) poses treatment challenges in elderly and comorbid patients. Radiation therapy (RT) is often employed for locoregional control. This study aimed to determine progression-free survival (PFS) and overall survival (OS) outcomes achieved with upfront RT in unresectable HNcSCC.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!