A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection of occult lung impairment in welders by induced sputum particles and breath oxidation. | LitMetric

Background: We evaluated particulate matter in combined induced sputum (IS) and oxidation in exhaled breath condensate (EBC) to test whether underlying inflammatory changes are present in asymptomatic welders.

Methods: Thirty welders from the Israel Defense Forces exposed to aluminum/iron (Group 1) or to cadmium/chromium/iron/lead/nickel (Group 2, N = 16) and 27 non-exposed administrators were studied. IS was recovered, particle size distribution, hydrogen peroxide and pH were measured, and exhaled breath condensate was collected.

Results: Group 2 had a higher % neutrophils than all other participants (P = 0.0001) and a higher % particles >2 microm in diameter (P = 0.0017). Percent particles and years of exposure highly correlated (P = 0.051). All welders EBC samples had higher concentrations of hydrogen peroxide than controls (P = 0.0001). pH was lower only for Group 2 (P = 0.0001).

Conclusions: Combined IS and EBC measurements detect underlying inflammation in airways of asymptomatic welders. It emerged that airway inflammation is present in asymptomatic welders, and that the particle burden, inflammatory cells, and level of oxidative stress are a function of the type and the duration of welding. Am. J. Ind. Med. 51:503-511, 2008.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ajim.20586DOI Listing

Publication Analysis

Top Keywords

induced sputum
8
exhaled breath
8
breath condensate
8
hydrogen peroxide
8
asymptomatic welders
8
welders
5
detection occult
4
occult lung
4
lung impairment
4
impairment welders
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!