A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design and instrumentation of new devices for performing appendectomy at colonoscopy (with video). | LitMetric

Background: There is increasing interest in natural orifice surgery (NOS). Because the lumen of the appendix is connected to the cecum, a minimally invasive method for removing the appendix by colonoscopy may be feasible.

Objectives: Our purpose was to design, develop, and test new devices for inverting and removing the appendix by colonoscopy.

Design: Prospective prototype development program.

Setting: University-based study in 25 colons from adult human cadavers.

Interventions And Methods: Various prototypes were evaluated by inserting them into the appendiceal orifice to its luminal tip, with the intent to invert the appendix in a controlled fashion into the lumen of the cecum. The advantage of using a tubular structure as a counterforce to aid inversion of the appendix was evaluated. When inversion was incomplete, the growing tissue strain was relieved by endoluminal incision of the mesenteric side of the appendix. Closure methods with endoloops or ligating loops were studied. Appendiceal resection was completed by snare diathermy, leaving an inverted intraluminal stump.

Main Outcome Measurement: Ability to invert the appendix into the cecum.

Results: The mean appendix length and luminal diameter were 84 +/- 23 mm and 4.9 +/- 1.2 mm, respectively. It was possible to advance various types of inversion devices to the tip of the appendiceal lumen. Partial inversion of the appendix was successful in 22 of 25 tests. Mesenteric tissue tension, tissue volume, and device slippage were the main reasons for incomplete inversion. The complete inversion was achieved with a combination of vacuum, tip grip, counterforce at the appendix base, and eventually endoluminal incision.

Conclusions: The inversion of the human appendix by colonoscopy seems feasible and may be an alternative approach to conventional appendectomy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gie.2008.02.024DOI Listing

Publication Analysis

Top Keywords

appendix
11
removing appendix
8
appendix colonoscopy
8
invert appendix
8
inversion appendix
8
inversion
7
design instrumentation
4
instrumentation devices
4
devices performing
4
performing appendectomy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!