A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

On-chip, time-correlated, fluorescence lifetime extraction algorithms and error analysis. | LitMetric

On-chip, time-correlated, fluorescence lifetime extraction algorithms and error analysis.

J Opt Soc Am A Opt Image Sci Vis

Institute for Micro and Nano Systems, School of Engineering and Electronics, University of Edinburgh, King's Buildings, Edinburgh, Scotland, UK.

Published: May 2008

A new, simple, and hardware-only fluorescence-lifetime-imaging microscopy (FLIM) is proposed to implement on-chip lifetime extractions, and their signal-to-noise-ratio based on statistics theory is also deduced. The results are compared with Monte Carlo simulations, giving good agreement. Compared with the commonly used iterative least-squares method or the maximum-likelihood-estimation- (MLE-) based, general purpose FLIM analysis software, our algorithm offers direct calculation of fluorescence lifetime based on the collected photon counts stored in on-chip counters and therefore delivers faster analysis for real-time applications, such as clinical diagnosis. Error analysis considering timing jitter based on statistics theory is carried out for the proposed algorithms and is also compared with MLE to obtain optimized channel width or measurement window and bit resolution of the time-to-digital converters for a given accuracy. A multi-exponential, pipelined fluorescence lifetime method based on the proposed algorithms is also introduced. The performance of the proposed methods has been tested on mono-exponential and four-exponential decay experimental data.

Download full-text PDF

Source
http://dx.doi.org/10.1364/josaa.25.001190DOI Listing

Publication Analysis

Top Keywords

fluorescence lifetime
12
error analysis
8
based statistics
8
statistics theory
8
proposed algorithms
8
based
5
on-chip time-correlated
4
time-correlated fluorescence
4
lifetime
4
lifetime extraction
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!