A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Adolescent use of insulin and patient-controlled analgesia pump technology: a 10-year Food and Drug Administration retrospective study of adverse events. | LitMetric

Adolescent use of insulin and patient-controlled analgesia pump technology: a 10-year Food and Drug Administration retrospective study of adverse events.

Pediatrics

Division of Postmarket Surveillance, Office of Surveillance and Biometrics, Food and Drug Administration, Rockville, Maryland 20850, USA.

Published: May 2008

Objectives: From January 1, 2005, through December 31, 2005, the Food and Drug Administration received 5 adolescent death reports associated with the use of insulin pumps, raising concerns about use of this device in this age group. To understand better the types of infusion pump-related problems in adolescents, we performed a comprehensive evaluation of insulin and patient-controlled analgesic pump-related adverse events reported for adolescents that were received by the Food and Drug Administration from 1996 to 2005.

Methods: A search for medical device adverse event reports from January 1, 1996 through December 31, 2005, involving insulin pumps or patient-controlled analgesic pumps used by patients who were aged 12 to 21 years was conducted in the Food and Drug Administration's Manufacturer and User Facility Device Experience Database. Reports were reviewed for demographic characteristics, type of adverse event, and patient morbidity, and potential contributory factors were classified from narratives in the reports.

Results: A total of 1674 reports were identified: 1594 for insulin pumps and 53 for patient-controlled analgesic pumps. In reports of insulin pump events, there were 13 reported deaths, 2 reports that indicated possible suicide attempts, and several additional reports indicating severe hypoglycemic or hyperglycemic events that seemed to be device-related. A total of 102 (6.4%) insulin-pump reports highlighted factors that may have contributed to the adverse event, including problems associated with compliance, education, sports-related activities, and dropping or damaging the pump. Eighty-two percent of cases involving the insulin pump resulted in hospitalization. Half of the reports involving patient-controlled analgesic pumps indicated that the patient received an excess of medication; tampering and noncompliance were evident in some cases.

Conclusions: Adolescents are a special population who deserve careful consideration of risk and benefit for use of device technology. Studies need to further identify safety problems in this age group.

Download full-text PDF

Source
http://dx.doi.org/10.1542/peds.2007-1707DOI Listing

Publication Analysis

Top Keywords

food drug
16
patient-controlled analgesic
16
drug administration
12
insulin pumps
12
adverse event
12
analgesic pumps
12
reports
9
insulin patient-controlled
8
adverse events
8
december 2005
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!